Modeling and Predicting Tissue Movement and Deformation for High Intensity Focused Ultrasound Therapy

نویسندگان

  • Xiangyun Liao
  • Zhiyong Yuan
  • Qianfeng Lai
  • Jiaxiang Guo
  • Qi Zheng
  • Sijiao Yu
  • Qianqian Tong
  • Weixin Si
  • Mingui Sun
  • Alena Talkachova
چکیده

PURPOSE In ultrasound-guided High Intensity Focused Ultrasound (HIFU) therapy, the target tissue (such as a tumor) often moves and/or deforms in response to an external force. This problem creates difficulties in treating patients and can lead to the destruction of normal tissue. In order to solve this problem, we present a novel method to model and predict the movement and deformation of the target tissue during ultrasound-guided HIFU therapy. METHODS Our method computationally predicts the position of the target tissue under external force. This prediction allows appropriate adjustments in the focal region during the application of HIFU so that the treatment head is kept aligned with the diseased tissue through the course of therapy. To accomplish this goal, we utilize the cow tissue as the experimental target tissue to collect spatial sequences of ultrasound images using the HIFU equipment. A Geodesic Localized Chan-Vese (GLCV) model is developed to segment the target tissue images. A 3D target tissue model is built based on the segmented results. A versatile particle framework is constructed based on Smoothed Particle Hydrodynamics (SPH) to model the movement and deformation of the target tissue. Further, an iterative parameter estimation algorithm is utilized to determine the essential parameters of the versatile particle framework. Finally, the versatile particle framework with the determined parameters is used to estimate the movement and deformation of the target tissue. RESULTS To validate our method, we compare the predicted contours with the ground truth contours. We found that the lowest, highest and average Dice Similarity Coefficient (DSC) values between predicted and ground truth contours were, respectively, 0.9615, 0.9770 and 0.9697. CONCLUSION Our experimental result indicates that the proposed method can effectively predict the dynamic contours of the moving and deforming tissue during ultrasound-guided HIFU therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Simulating temperature distribution of high-intensity focused ultrasound during bone treatments

Background/introduction To help improve therapeutic results for treatment of bone tumors, high intensity focused ultrasound (HIFU) is being investigated as a non-invasive alternative to surgery and radiotherapy. HIFU ablative treatments require an imaging modality for guidance, and magnetic resonance (MR) imaging is currently the strongest choice as it is able to provide temperature mapping thr...

متن کامل

Beamforming for Therapy with High Intensity Focused Ultrasound (hifu) Using Quantitative Schlieren

The requirements for beamforming in high intensity focused ultrasound (HIFU) for tissue destruction are substantially different than those for diagnostic imaging. High numerical aperture and CW efficiency are desirable for tissue destruction, while depth of focus and broadband sensitivity are key to good imaging. When the same transducer must be used for ablation and imaging some compromises mu...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics

Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...

متن کامل