Evaluation of the Technicon Axon analyser

نویسندگان

  • C. Martínez
  • M. Márquez
  • M. Cortés
  • J. Mercé
  • J. Rodriguez
  • F. González
چکیده

An evaluation of the Technicon Axon analyser was carried out following the guidelines of the 'Sociedad Española de Química Clínica' and the European Committee for Clinical Laboratory Standards.A photometric study revealed acceptable results at both 340 nm and 404 nm. Inaccuracy and imprecision were lower at 404 nm than at 340 nm, although poor dispersion was found at both wavelengths, even at low absorbances. Drift was negligible, the imprecision of the sample pipette delivery system was greater for small sample volumes, the reagent pipette delivery system imprecision was acceptable and the sample diluting system study showed good precision and accuracy.Twelve analytes were studied for evaluation of the analyser under routine working conditions. Satisfactory results were obtained for within-run imprecision, while coefficients of variation for betweenrun imprecision were much greater than expected. Neither specimenrelated nor specimen-independent contamination was found in the carry-over study. For all analytes assayed, when comparing patient sample results with those obtained in a Hitachi 737 analyser, acceptable relative inaccuracy was observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of a Technicon SMAC2/RA1000 System with an American Monitor Parallel during normal service work

To meet the requirements of an increasing biochemical work-load, manufacturers have developed large and expensive computer-controlled analytical systems. Therefore the choice ofmain analyser for a clinical biochemistry department is a major decision with long-term financial implications. Advice is usually sought from current users, but this is often more anecdotal than factual and certainly not...

متن کامل

Operator-free flow injection analyser

A flow injection analyser has been constructed to allow an operator-free determination of up to 40 samples. Besides the usual FIA apparatus, the analyser includes a home-made sample introduction device made with three electromechanical three-way valves and an auto-sampler from Technicon which has been adapted to be commanded by an external digital signal. The analyser is controlled by a single ...

متن کامل

Evaluation of the Olympus Demand random access chemistry analyser

We evaluated the Olympus Demand as a cost-saving measure, as a back up to a Technicon SMAC I, and to be the primary instrument for enzyme analysis. In general, it wasfound to be precise, reliable, easy to operate, but with only average turn-around time capabilities. Technically there were several limitations: (1) significant bilirubin interference in the analysis of serum bicarbonate and creati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 12  شماره 

صفحات  -

تاریخ انتشار 1990