What limits detection and resolution of short-wavelength sinusoidal gratings across the retina?
نویسندگان
چکیده
Peripheral resolution acuity for achromatic gratings is known to be limited by the density of the underlying ganglion cell sampling array. After confirming isolation of the short-wavelength sensitive (SWS) system using chromatic adaptation methods, we wished to determine if resolution is limited by blue/yellow ganglion cell sampling (evidenced by a superiority of detection over resolution acuity and the perception of aliasing) and thus directly related to SWS-driven ganglion cell density. We measured detection and resolution acuity between 0 degrees and 35 degrees, using blue sinusoidal gratings superimposed on a yellow adapting background which ranged in intensity from 2.5 to 4.7logTrolands. At all locations, a break could be observed in the acuity vs. illumination curves followed by a plateau. Detection and resolution acuity were the same for low background intensities, but resolution acuity was lower than detection at higher intensities, accompanied by observations of chromatic aliasing. SWS resolution is sampling-limited across the retina and agrees well with predicted performance based on anatomical estimates of small bistratified ganglion cell density.
منابع مشابه
Peripheral detection and resolution with mid-/long-wavelength and short-wavelength sensitive cone systems.
This study compared neural resolution and detection limits of the human mid-/long-wavelength and short-wavelength cone systems with anatomical estimates of photoreceptor and retinal ganglion cell spacings and sizes. Detection and resolution limits were measured from central fixation out to 35° eccentricity across the horizontal visual field using a modified Lotmar interferometer. The mid-/long-...
متن کاملShort-wavelength acuity: optical factors affecting detection and resolution of blue–yellow sinusoidal gratings in foveal and peripheral vision
Previous studies have indicated that peripheral achromatic grating resolution is limited by the sampling density of the neural array (sampling limited), and largely unaffected by large amounts of optical defocus and significant changes in luminance. Under certain conditions, peripheral short-wavelength sensitive (SWS) grating acuity is also sampling limited. We wished to determine how the sampl...
متن کاملNeural bandwidth of veridical perception across the visual field
Neural undersampling of the retinal image limits the range of spatial frequencies that can be represented veridically by the array of retinal ganglion cells conveying visual information from eye to brain. Our goal was to demarcate the neural bandwidth and local anisotropy of veridical perception, unencumbered by optical imperfections of the eye, and to test competing hypotheses that might accou...
متن کاملOptical pulse compression based on nonlinear silicon waveguides and chirped Bragg gratings
Due to the growing demand for higher bandwidth, employing optical devices instead of electronic devices in data transmission systems has attracted much attention in recent years. Optical switches, modulators and wavelength converters are a few examples of the required optical devices. CMOS compatible fabrication of these devices, leads to much more growing of this technology. Optical pulse comp...
متن کاملTemporal summation of moving images by the human visual system.
Measurements of threshold visibility were made as a function of duration of stimulus exposure for small moving dot targets, drifting sinusoidal gratings and moving patches of sinusoidal gratings, to investigate how the human visual nervous system summates over time signals arising from stimuli in motion. At image speeds of less that 16 deg/s, temporal summation is as strong and as extended for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 42 شماره
صفحات -
تاریخ انتشار 2002