Noninvasive assessment of the circle of Willis in cerebral ischemia: the potential of CT angiography and contrast-enhanced transcranial color-coded duplexsonography.

نویسندگان

  • G Gahn
  • J Gerber
  • S Hallmeyer
  • H Reichmann
  • R von Kummer
چکیده

Thirty-four patients with acute hemispheric ischemic strokes underwent both CT angiography and contrast-enhanced transcranial color-coded duplexsonography (TCCD) to study the effectiveness of the combined noninvasive techniques for evaluation of the circle of Willis. In 3/34 patients, CT angiography and contrast-enhanced TCCD demonstrated middle cerebral artery (MCA) occlusion, in 5 others MCA stenosis. A severe posterior cerebral artery stenosis was missed by CT angiography. In 8 patients, contrast-enhanced TCCD failed because of poor bone windows. In these patients, CT angiography was normal. CT angiography and contrast-enhanced TCCD are complementary noninvasive diagnostic tools. Disagreements between the diagnostic findings of these methods still need further evaluation by digital subtraction angiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-enhanced transcranial color-coded duplexsonography in stroke patients with limited bone windows.

BACKGROUND AND PURPOSE Thickening of the temporal bone in stroke-age patients may obviate sonographic evaluation of the circle of Willis in 20% to 30% of patients. We assessed the diagnostic efficacy of contrast-enhanced transcranial color-coded duplexsonography (TCCD) for noninvasive evaluation of the circle of Willis in stroke patients with limited bone windows. METHODS Of 171 consecutive p...

متن کامل

Echo-enhanced transcranial color-coded duplexsonography to study collateral blood flow in patients with symptomatic obstructions of the internal carotid artery and limited acoustic bone windows.

We prospectively evaluated 30 consecutive patients with echo-enhanced transcranial color-coded duplexsonography (TCCD) and correlative transfemoral digital subtraction angiography to assess the diagnostic efficacy of echo-enhanced TCCD for evaluation of collateral pathways through the circle of Willis in patients with limited acoustic bone windows and critical symptomatic carotid disease. Echo-...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Does anatomical completeness of the circle of Willis correlate with sufficient cross-perfusion during unilateral cerebral perfusion?

OBJECTIVES The aim of the study was to evaluate the role of anatomical completeness of the circle of Willis for sufficient brain perfusion during unilateral cerebral perfusion and the methodology of the preoperative and intraoperative functional assessments of adequate cross-perfusion. METHODS This prospective observational study included all elective patients (99) who underwent elective open...

متن کامل

بررسی واریاسیونهای آناتومیک حلقه عروقی مغز(حلقه ویلیس) از طریق آنژیوگرافی مغزی

ABSTRACT Anatomical variations have great importance among various medical disciplins. The significance of these variations differ from some points of view including system, site and degree of variation. Vascular system is a common site of variations. The importance of this system in supplying the organs, specially the brain has made it to be in focus for its variations. The main sourc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cerebrovascular diseases

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 1999