Current Control of a 3-phase Electric Arc Furnace Using Fuzzy Logic

نویسندگان

  • Loredana GHIORMEZ
  • Manuela PĂNOIU
چکیده

This paper presents a current control for a three-phase electric arc furnace of direct action. In order to do this, a fuzzy control system is proposed. The fuzzy system is a Mamdani fuzzy model and the environment used is Matlab. It has the current deviations as inputs and electrode speeds as outputs. Modifying the position of the electrodes, different arc lengths will be achieved. Also, a simulation of the proposed fuzzy control system is performed in two modes for testing the effectiveness of the proposed fuzzy system. First mode consists of using the fuzzy simulation tool and the second mode consists in implementing of the fuzzy control system in the Simulink/Matlab.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

G. Shabib-02

This paper investigates the control strategy for the electrical energy input to three phase electric arc ferrosilicon furnace. The classical PD fuzzy logic controller has two inputs. These inputs are the error in the V-I characteristic and the rate of the error in V-I characteristic. When the simulation result of this controller is compared with conventional PD type, it was shown that requires ...

متن کامل

Fuzzy Logic Control of Three Phase Submerged Arc Ferrosilicon Furnace

Research is made into the fuzzy control of electrode regulator systems of submerged electrical arc ferrosilicon furnace EAF. The equations of the electrode currents and furnace resistances are derived based on certain model for the submerged arc ferrosilicon furnace. This model takes into consideration the walls of furnace and the heat losses into external medium in addition to the heat transfe...

متن کامل

A Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method

An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...

متن کامل

Analysis of Different Loads with Multi-techniques Using D- Statcom

Due to the rapid growth of non-linear loads, such as power electronic control equipments and Electric arc furnace (EAF) power quality problems such as harmonics and voltage flicker are introduced in the power system. It occurs because of the time-varying and nonlinear behaviour of the Load. Arc furnaces are used in industries for induction heating and welding. Hence an Electric arc furnace mode...

متن کامل

A Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015