Coronary flow--pressure relationship distal to epicardial stenosis.

نویسندگان

  • Nobuhiro Tanaka
  • Kenji Takazawa
  • Kazuhiro Takeda
  • Masaru Aikawa
  • Naohisa Shindo
  • Kazutaka Amaya
  • Yuichi Kobori
  • Akira Yamashina
چکیده

To assess the coronary flow velocity - pressure relationship distal to a stenosis, and to evaluate the influence of microvascular abnormalities on this relationship, coronary flow velocity and coronary pressure were measured simultaneously in 38 patients (42 vessels). The instantaneous peak coronary flow velocity was plotted against the simultaneous measured distal coronary pressure, and the slope of the relation in the phase of diastolic flow decrease was calculated as the flow - pressure slope index (FPSI) and the X-intercept of the slope was calculated as zero-flow pressure (Pzf). The slope of the curve increased from 2.0+/-2.6 to 4.5+/-4.1 (p<0.001) and the X-intercept decreased from 42+/-16 to 27+/-13 mmHg (p<0.001) after papaverine injection. After successful coronary intervention, Pzf increased from 23+/-10 to 35+/-11 (p<0.01) and FPSI decreased from 6.8+/-5.1 to 3.5+/-1.8 (p<0.05). Pzf was higher in patients with an old myocardial infarction. It is feasible to assess the relationship between coronary flow and pressure distal to a stenosis in the clinical setting, and the relationship may provide additional information regarding coronary microcirculation. Microvascular abnormalities may play an important role in the coronary flow - pressure relationship distal to stenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارتباط TFC) TIMI Frame Count) با کسر ذخیره جریانی (FFR) در بیماران مبتلا به تنگی متوسط عروق کرونر که تحت آنژیوگرافی کرونر قرار می‌گیرند

Background and Objective: Thrombolysis in myocardial infarction (TIMI) frame count (TFC) is an objective and quantitative index of coronary flow, and myocardial fractional flow reserve (FFR) is a lesion-specific index for epicardial coronary stenosis. Currently, FFR is the most valid tool for decision making in coronary interventions. However, it incurs relatively high costs and it is not reimb...

متن کامل

Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study

BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...

متن کامل

Microvascular resistance is not influenced by epicardial coronary artery stenosis severity: experimental validation.

BACKGROUND The effect of epicardial artery stenosis on myocardial microvascular resistance remains controversial. Recruitable collateral flow, which may affect resistance, was not incorporated into previous measurements. METHODS AND RESULTS In an open-chest pig model, distal coronary pressure was measured with a pressure wire, and the apparent minimal microvascular resistance was calculated d...

متن کامل

Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation.

The pressure-flow characteristics of 100 left circumflex stenoses in 10 chronically instrumented unsedated dogs were studied under resting conditions and during pharmacological coronary vasodilation. At rest, the pressure loss (deltaP) due to a stenosis and arterial flow velocity (V) were related by the equation, deltaP = FV + SV2, where F is the coefficient of pressure loss due to viscous fric...

متن کامل

Experimental Basis of Determining Maximum Coronary, Myocardial, and Collateral Blood Flow by Pressure Measurements for Assessing Functional Stenosis Severit Before and After Percutaneous Transluminal Coronary Angioplasty

Background. Severity of coronary artery stenosis has been defined in terms of geometric dimensions, pressure gradient-flow relations, resistance to flow and coronary flow reserve, or maximum flow capacity after maximum arteriolar vasodilation. A direct relation between coronary pressure and flow, however, may only be presumed if the resistances in the coronary circulation are constant (and mini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 67 6  شماره 

صفحات  -

تاریخ انتشار 2003