1-Year Outcomes of Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Stents: A Propensity-Matched Comparison of the GHOST-EU and XIENCE V USA Registries.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to compare the 1-year outcomes of the ABSORB everolimus-eluting bioresorbable scaffold (BRS) (Abbott Vascular, Santa Clara, California) and the XIENCE everolimus-eluting stent (EES) (Abbott Vascular) in patients undergoing percutaneous coronary intervention. BACKGROUND Randomized studies of the ABSORB BRS have been performed in selected patient and lesion scenarios. The available registries of the ABSORB BRS reflect real-world practice more closely compared with randomized studies, but most of them are limited by the small sample size and the lack of comparative outcomes versus second-generation drug-eluting stents. METHODS A total of 1,189 consecutive patients treated with ABSORB BRS from the GHOST-EU (Gauging coronary Healing with bioresorbable Scaffolding plaTforms in EUrope) registry and 5,034 patients treated with XIENCE EES from the XIENCE V USA registry were analyzed. Clinical outcomes were compared with the use of propensity-score matching techniques and reported as Kaplan-Meier estimates and absolute risk difference (D) with 95% confidence intervals (CIs). The primary endpoint was a device-oriented composite endpoint, including cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization at 1-year follow-up. RESULTS After propensity score matching was performed for the entire population (N = 6,223), there were 905 matched pairs of patients. In the matched cohort (N = 1,810), there was no significant difference between ABSORB BRS and XIENCE EES in the risk of device-oriented composite endpoint at 1 year (5.8% vs. 7.6%, D = -1.8 [95% CI: -4.1 to 0.5]; p = 0.12). Cardiac death was less likely to occur in the ABSORB BRS group (0.7% vs. 1.9%, D = -1.2 [95% CI: -2.2 to 0.2]; p = 0.03), and a trend toward a reduction in myocardial infarction was noted with ABSORB BRS compared with XIENCE EES (2.4% vs. 4.0%, D = -1.6 [95% CI: -3.2 to 0.0]; p = 0.07). Conversely, no differences in ischemia-driven target lesion revascularization (4.6% vs. 3.5%, D = 1.1 [95% CI: -0.7 to 2.9]; p = 0.22) and definite or probable device thrombosis (1.8% vs. 1.1%, D = 0.7 [95% CI: -0.4 to 1.8]; p = 0.23) were detected between ABSORB BRS and XIENCE EES. CONCLUSIONS In a contemporary large cohort of patients undergoing percutaneous coronary intervention with ABSORB BRS, the combined rate of ischemic events at 1 year was low and nonsignificantly different compared with matched patients treated with XIENCE EES.
منابع مشابه
Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.
OBJECTIVES The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. BACKGROUND The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the X...
متن کاملTension gastrothorax mimicking acute coronary syndrome and causing cardiac arrest.
Veldhof S, Rapoza R, Onuma Y, Garcia-Garcia HM, Chevalier B. ABSORB II randomized controlled trial: a clinical evaluation to compare the safety, efficacy, and performance of the Absorb everolimus-eluting bioresorbable vascular scaffold system against the XIENCE everolimus-eluting coronary stent system in the treatment of subjects with ischemic heart disease caused by de novo native coronary art...
متن کاملImpact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.
OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from t...
متن کاملLong-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents
Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...
متن کاملNext-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V®)
Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES), such as sirolimus-eluting (Cypher) and paclitaxel-eluting stents (Taxus), have further improved results of percutaneous coronary intervention (PCI) by improving early r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 9 5 شماره
صفحات -
تاریخ انتشار 2016