Does a Low-wall Coverage Stent Have a Flow Diverting Effect in Small Aneurysms?
نویسندگان
چکیده
BACKBROUND AND PURPOSE The flow diverting effect of a low-wall coverage stent remains controversial. We evaluted patients who underwent stenting for small aneurysms with a low but potential risk of growth and reviewed related literature. MATERIALS AND METHODS We evaluated 9 small aneurysms among 19 unruptured intracranial aneurysms from eight patients who underwent stenting. The patients had unexplainable severe headache (n = 8), aneurysm originating from the anterior choroidal artery (n = 3), potential growth or rupture risks including hypertension (n = 5), and multiple aneurysms (n = 6). Stents with a relatively low-wall coverage ratio (8-10%) were used. Clinical and angiographic outcomes were assessed. RESULTS One (n = 8) or two stents (n = 1) were used without any procedural difficulties or complications. Although no immediate changes of aneurysm morphology were observed, aneurysms decreased in size (n = 8) when examined by DSA (n = 8) or MRA (n = 1) during a median 28.9-month follow-up. There were no adverse events, including thromboembolism, aneurysm rupture, or stent movement during a median 31.9-month clinical follow-up (range: 17-69 months). CONCLUSION Although a variable degree of aneurysm size decrease may not prevent further growth or rupture of small aneurysms, stenting with a low-wall coverage ratio may have some advantageous hemodynamic effect. Flow modification of stent architecture vs. aneurysm characteristics, including size and location, on long-term outcome, requires further clarification.
منابع مشابه
Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.
BACKGROUND AND PURPOSE Computational fluid dynamics modeling is useful in the study of the hemodynamic environment of cerebral aneurysms, but patient-specific measurements of boundary conditions, such as blood flow velocity and pressure, have not been previously applied to the study of flow-diverting stents. We integrated patient-specific intravascular blood flow velocity and pressure measureme...
متن کاملProspective Study of Early MRI Appearances following Flow-Diverting Stent Placement for Intracranial Aneurysms.
BACKGROUND AND PURPOSE MR imaging findings of aneurysm enlargement, aneurysm wall enhancement, perianeurysmal edema, and embolic phenomena following deployment of flow-diverting stents may be relevant to those patients who subsequently experience procedure-related intracranial hemorrhage. We sought to document the routine early postoperative MR imaging findings following flow-diverting stent in...
متن کاملEffects of flow-diverting device oversizing on hemodynamics alteration in cerebral aneurysms.
BACKGROUND AND PURPOSE Flow-diverting devices are increasingly being considered for large or giant aneurysms with wide necks, which are difficult to treat with coils or clips. These devices are often oversized to achieve good positioning against the artery wall. The objective of this study was to analyze the effect of oversized flow-diverting devices in altering aneurysmal flows and creating he...
متن کاملActual metal coverage at the neck is critical for flow-diverting stents in treating intracranial aneurysms.
We read the interesting article by Schneiders et al, entitled “A Flow-Diverting Stent Is Not a Pressure-Diverting Stent.” The authors measured intra-aneurysmal pressure before, during, and after placement of a flow-diverting (FD) stent and found that the pressure inside the aneurysm momentarily decreased during placement but was restored to baseline values within minutes. They agreed with the a...
متن کاملBlood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models
PURPOSE The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. METHODS Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -