Intraocular lens implantation position sensitivity as a function of refractive error.

نویسندگان

  • Huanqing Guo
  • Alexander Goncharov
  • Chris Dainty
چکیده

PURPOSE To quantify the change in ocular aberrations due to intraocular lens (IOL) implantation position errors for pseudo-phakic eyes with different refractive errors. METHODS The theoretical part of this work was based on ray-tracing in emmetropic and myopic eye models. The possible misalignments i.e. the decentration, tilt and axial translation, of the IOLs were statistically combined together and analysed using Monte-Carlo simulations. Spherical IOLs with a 3 and 5 mm pupil and an aspheric IOL with a 5 mm pupil were analysed as a function of refractive error. In the experimental part of the work, we built an IOL optical test bench including a model eye. The white light discrete point spread functions of misaligned IOLs were recorded by a CCD and we compared the change of the spread function as a result of misalignments for two spherical IOLs with different optical powers. RESULTS The Monte-Carlo simulations showed that the average root-mean-square spot size at the retinal plane decreased with increasing myopic refractive error, i.e. lower power IOL. The experiments showed that a lower optical power spherical IOL had a less distributed point spread function than a higher optical power IOL, which supported the results of the simulation. CONCLUSION Regarding IOLs designed for myopic patients, low power IOLs (for high myopes) were shown to be less sensitive to the misalignment than high power ones. Aspheric IOLs were more sensitive to position errors than spherical IOLs under the same conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Co-Implantation of a Capsular Tension Ring on Clinical Outcomes after Cataract Surgery with Monofocal Intraocular Lens Implantation

PURPOSE The objective was to evaluate the effect of co-implantation of a preloaded capsular tension ring (CTR) and aberration-free monofocal intraocular lens (IOL) on clinical outcomes and visual quality after cataract surgery. MATERIALS AND METHODS Patients who underwent cataract surgery were randomized into two groups that were implanted with a CTR and IOL (group 1, 26 eyes) or an IOL only ...

متن کامل

Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...

متن کامل

Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.

IMPORTANCE Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. OBJECTIVE To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism...

متن کامل

Comparison of higher order aberrations and contrast sensitivity after LASIK, Verisyse phakic IOL, and Array multifocal IOL.

PURPOSE To evaluate higher order aberrations and contrast sensitivity after LASIK, implantation of the Verisyse phakic intraocular lens (IOL), and refractive lens exchange with the Array multifocal IOL. METHODS In a prospective, non-randomized case series, LASIK was performed in 20 eyes with the Technolas 217z excimer laser (Bausch & Lomb, Rochester, NY), a Verisyse phakic IOL (AMO Inc, Santa...

متن کامل

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

PURPOSE To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). SETTING Private practice surgery center, Valencia, Spain. DESIGN Cohort study. METHODS Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; def...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2012