Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography.

نویسندگان

  • Pol Grasland-Mongrain
  • François Destrempes
  • Jean-Martial Mari
  • Rémi Souchon
  • Stefan Catheline
  • Jean-Yves Chapelon
  • Cyril Lafon
  • Guy Cloutier
چکیده

Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an 'acousto-electrical speckle' in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Electrical Anisotropy and Acoustic Inhomogeneity in Magnetoacoustic Tomography with Magnetic Induction

Magnetoacoustic tomography with magnetic induction(MAT-MI) is a noninvasive technology for imaging the distribution of electrical impedance in biological tissue. In the sameple, a time-varying magnetic field induces currents. A static magnetic field interact with the currents to produce a Lorentz force. Consequently, the sample will emit ultrasonic waves by the Lorentz force. The objective of t...

متن کامل

Electric Impedance

Electrical impedance tomogram of the mammary gland (EIM). Seven planes of scanning. In the sixth and the seventh scans, a retromammary tissue is visualized. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasoundbased medical imaging technique. In this study, a new platform based on electric cell-substrate impedance sensing ...

متن کامل

Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review.

Magnetoacoustic tomography with magnetic induction (MAT-MI) is a noninvasive imaging method developed to map electrical conductivity of biological tissue with millimeter level spatial resolution. In MAT-MI, a time-varying magnetic stimulation is applied to induce eddy current inside the conductive tissue sample. In the presence of a static magnetic field, the Lorentz force acting on the induced...

متن کامل

The Application of Multi-Layer Artificial Neural Networks in Speckle Reduction (Methodology)

Optical Coherence Tomography (OCT) uses the spatial and temporal coherence properties of optical waves backscattered from a tissue sample to form an image. An inherent characteristic of coherent imaging is the presence of speckle noise. In this study we use a new ensemble framework which is a combination of several Multi-Layer Perceptron (MLP) neural networks to denoise OCT images. The noise is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 60 9  شماره 

صفحات  -

تاریخ انتشار 2015