Calibration of spiral-readout image-plate detectors
نویسندگان
چکیده
An improved method for intensity-uniformity calibration of diffraction data collected on spiral-readout image-plate (IP) systems is described. This technique is applicable to all types of spiral-readout IP detectors. The procedure utilizes an attenuated direct-beam scan of the IP to generate a radial-sensitivity calibration table. Exposure and scanning of the calibration frame are done on the same time scale as typical data collections, and require no additional equipment. Speci®c examples are presented for use with Mac Science DIP2000 systems. The new radial calibration is shown to reduce signi®cantly structure-based R factors. The improved radial calibration is also shown to lower Rmerge when the IP is offset from the beam center. In addition to improving data quality and statistics, this method provides a quick and simple diagnostic tool to monitor changes in the sensitivity of the IP detector as a function of age.
منابع مشابه
Microchannel Plate Imaging Detector Technologies for Uv Instruments
There has been significant progress over the last few years in the development of technologies for microchannel plate (MCP) imaging detectors in the ultraviolet. The nominal configuration of this type of detector consists of a photocathode to convert incoming radiation to photoelectrons, MCP’s to amplify the signals, followed by either an optical or electronic image readout scheme. Areas where ...
متن کاملEvaluation of Absorbed Dose of Critical Organ in Rando Phantom under Head, Abdomen and Pelvis Spiral CT Scan by Thermo Luminescent Dosimetery - TLD
Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...
متن کاملThe Calibration and Data Products of Galex
We describe the calibration status and data products pertaining to the GR2 and GR3 data releases of the Galaxy Evolution Explorer (GALEX ). These releases have identical pipeline calibrations that are significantly improved over the GR1 data release.GALEX continues to survey the sky in the far-ultraviolet (FUV, 154 nm) and near-ultraviolet (NUV, 232 nm) bands, providing simultaneous imaging wit...
متن کاملThe Calibration and Data Products of the Galaxy Evolution Explorer
We describe the calibration status and data products pertaining to the GR2 and GR3 data releases of the Galaxy Evolution Explorer (GALEX). These releases have identical pipeline calibrations that are significantly improved over the GR1 data release. GALEX continues to survey the sky in the Far Ultraviolet (FUV, ∼ 154 nm) and Near Ultraviolet (NUV, ∼ 232 nm) bands, providing simultaneous imaging...
متن کاملCharacterization and Calibration of Large Area Resistive Strip Micromegas Detectors
Resistive strip Micromegas detectors have been tested extensively as small detectors of about 10 x 10 cm2 in size and they work reliably at high rates of 100 kHz/cm2 and above. Tracking resolution well below 100μm has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m2 in size. To investigate possible differences...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999