Handcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
نویسندگان
چکیده
OBJECTIVE To test the agreement between two handcrafted devices and a cuff-specific manometer. METHODS The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1 and HD2). The data were compared using Wilcoxon and Spearman tests, the intraclass correlation coefficient (ICC) and limit-of-agreement analysis. RESULTS Cuff pressures assessed with handcrafted devices were significantly different from commercial device measurements (pressures were higher when measured with HD1 and lower with HD2). The ICCs between the commercial device and HD1 and HD2 were excellent (ICC = 0.8 p < 0.001) and good (ICC = 0.66, p < 0.001), respectively. However, the Bland- Altman plots showed wide limits of agreement between HD1 and HD2 and the commercial device. CONCLUSION The handcrafted manometers do not provide accurate cuff pressure measurements when compared to a cuff-specific device and should not be used to replace the commercial cuff manometers in mechanically ventilated patients.
منابع مشابه
Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملStudy of endotracheal tube cuff pressure and time of measurement among intensive care units patients
Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...
متن کاملبررسی اندازهگیری و کنترل فشار کاف لوله داخل تراشه بیماران بستری در بخش مراقبتهای ویژه
Background and Objective: The objective of this study was to investigate the endotracheal tube cuff (ETT) pressure in the intensive care unit (ICU) patients, who had been intubated. Meterials and Methods: All patients were placed in ICU during the last three month 2008. The endotracheal tube cuff (ETT) pressure in 308 cases was measured at twice by an expert. A standard manometer was used...
متن کاملEndotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure
BACKGROUND: Cuff pressure in endotracheal (ET) tubes should be in the range of 20-30 cm H2O. We tested the hypothesis that the tube cuff is inadequately inflated when manometers are not used. METHODS: With IRB approval, we studied 93 patients under general anesthesia with an ET tube in place in one teaching and two private hospitals. Anesthetists were blinded to study purpose. Cuff pressure in ...
متن کاملEffect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients
Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 27 شماره
صفحات -
تاریخ انتشار 2015