A Novel Method for Measuring Anterior Segment Area of the Eye on Ultrasound Biomicroscopic Images Using Photoshop

نویسندگان

  • Zhonghao Wang
  • Xuanwei Liang
  • Ziqiang Wu
  • Jialiu Lin
  • Jingjing Huang
چکیده

PURPOSE To describe a novel method for quantitative measurement of area parameters in ocular anterior segment ultrasound biomicroscopy (UBM) images using Photoshop software and to assess its intraobserver and interobserver reproducibility. METHODS Twenty healthy volunteers with wide angles and twenty patients with narrow or closed angles were consecutively recruited. UBM images were obtained and analyzed using Photoshop software by two physicians with different-level training on two occasions. Borders of anterior segment structures including cornea, iris, lens, and zonules in the UBM image were semi-automatically defined by the Magnetic Lasso Tool in the Photoshop software according to the pixel contrast and modified by the observers. Anterior chamber area (ACA), posterior chamber area (PCA), iris cross-section area (ICA) and angle recess area (ARA) were drawn and measured. The intraobserver and interobserver reproducibilities of the anterior segment area parameters and scleral spur location were assessed by limits of agreement, coefficient of variation (CV), and intraclass correlation coefficient (ICC). RESULTS All of the parameters were successfully measured by Photoshop. The intraobserver and interobserver reproducibilities of ACA, PCA, and ICA were good, with no more than 5% CV and more than 0.95 ICC, while the CVs of ARA were within 20%. The intraobserver and interobserver reproducibilities for defining the spur location were more than 0.97 ICCs. Although the operating times for both observers were less than 3 minutes per image, there was significant difference in the measuring time between two observers with different levels of training (p<0.001). CONCLUSION Measurements of ocular anterior segment areas on UBM images by Photoshop showed good intraobserver and interobserver reproducibilties. The methodology was easy to adopt and effective in measuring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA).

OBJECTIVE To describe a novel approach to measuring anterior chamber angle dimensions and configurations. METHODS Sixty-nine images were selected randomly from the ultrasound biomicroscopic image database to develop the algorithm. Thirty images were selected for further analyses. The value of each pixel of the 8-bit grayscale ultrasound biomicroscopic images was quantized into 0 (black) or 1 ...

متن کامل

To Estimate the Axial Elastic Modulus of Eye and Posterior Wall Thickness in Healthy Human Eye by Ultrasound Images and their Relation with Age and Gender

Introduction: Based on the invasive studies it has been shown that factors such as age, the progress of eye disorders, lens fibers compression and the biochemical changes of ocular matrix alter the physical characteristics and elastic properties of eye. In this study, a noninvasive method of estimating human eye elasticityis proposed and its relation with age and gender is evaluated using ultra...

متن کامل

Ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring.

AIM To perform ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by lens capsule and a Soemmering's ring and its resolution, and to elucidate the pathophysiology of this glaucoma. METHODS A woman with pseudophakic pupillary block glaucoma underwent successful neodymium:YAG (Nd:YAG) laser photodisruption of the lens capsule through a laser iridotomised colobom...

متن کامل

Ultrasound biomicroscopic measurement of anterior chamber angle in premature infants.

AIM To establish normative values for the anterior segment in premature infants in relation to postconceptional age and birth weight. METHODS Anterior segments were measured in 39 premature infants, 25 to 39 weeks' gestational age by use of ultrasound biomicroscopy and a muscle hook with topical anaesthesia. RESULTS Anterior chamber depth, trabecular-iris angle, angle opening (trabecular-ir...

متن کامل

Anterior segment implantation cysts. Ultrasound biomicroscopy with histopathologic correlation.

OBJECTIVE To correlate the clinical, histopathologic, and ultrasound biomicroscopic characteristics of anterior segment implantation cysts. METHODS We performed a retrospective review of 7 cases of secondary anterior segment implantation cysts. We reviewed the clinical history, visual acuity, clinical findings, and ultrasound biomicroscopic characteristics in all cases. Histopathologic correl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015