The everolimus-eluting stent in real-world patients: 6-month follow-up of the X-SEARCH (Xience V Stent Evaluated at Rotterdam Cardiac Hospital) registry.

نویسندگان

  • Yoshinobu Onuma
  • Neville Kukreja
  • Nicolo Piazza
  • Jannet Eindhoven
  • Chrysafios Girasis
  • Lisanne Schenkeveld
  • Ron van Domburg
  • Patrick W Serruys
چکیده

OBJECTIVES The purpose of this study was to investigate the impact of everolimus-eluting stents (EES) in comparison with bare-metal stents (BMS), sirolimus-eluting stents (SES), and paclitaxel-eluting stents (PES) on the 6-month clinical outcomes in an all-comer population. BACKGROUND EES have been shown to be effective in the context of randomized trials with selected patients. The effect of EES implantation in more complex, unselected patients cannot be directly extrapolated from these findings. METHODS In total, 649 consecutive unselected patients treated exclusively with EES were enrolled. Six-month clinical end points were compared with 3 historical cohorts (BMS, n = 450; SES, n = 508; and PES, n = 576). Major adverse cardiac events (MACE) were defined as a composite of all-cause mortality, myocardial infarction, or target vessel revascularization (TVR). RESULTS The patients treated with EES were older, presented more frequently with acute myocardial infarction, and had more complicated lesions than the other groups. The EES group demonstrated a higher incidence of all-cause mortality than the SES group and a lower incidence of TVR than the BMS group. Multivariate adjustment demonstrated that BMS was associated with higher TVR and MACE risk than EES (adjusted hazard ratio [HR] for TVR: 2.02 [95% confidence interval (CI): 1.11 to 3.67]; adjusted HR for MACE: 2.15 [95% CI: 1.36 to 3.42]); that SES had a clinical outcome similar to that of EES, and that PES had a higher risk of MACE than did EES (adjusted HR: 1.57 [95% CI: 1.02 to 2.44]). CONCLUSIONS This study suggests that the use of EES in an unselected population may be as safe as and more effective than BMS, may be as safe and effective as SES, may be as safe as PES, and may be more effective than PES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of the Second-generation Everolimus-eluting Stent Compared to the First-genereation Paclitaxel-eluting Stent in Patients Undergoing Percutaneous Coronary Intervention in Daily Practice

Objectives: To examine the cost-effectiveness of the second-generation everolimus-eluting stent (EES) compared to the first-generation paclitaxel-eluting stent (PES) in patients undergoing percutaneous coronary intervention (PCI) in daily practice. Methods: The cost-effectiveness analysis was based on data from the TAXUS Stent Evaluated at Rotterdam Cardiology Hospital (T-SEARCH) and XIENCE Ste...

متن کامل

Unprotected left main coronary artery stenting with everolimus (Xience V) drug-eluting stents: A single center retrospective experience

Objectives: We sought to evaluate the efficacy and safety of unrestricted implantation of everolimus eluting stent Xience V (EES-XV) in a cohort of realworld patients with unprotected left main coronary disease (ULMCD). Background: The second-generation EES-XV stent is currently one of the most commonly used drug-eluting stents in clinical practice. It has been shown to be superior to paclitaxe...

متن کامل

Clinical outcome following stringent discontinuation of dual antiplatelet therapy after 12 months in real-world patients treated with second-generation zotarolimus-eluting resolute and everolimus-eluting Xience V stents: 2-year follow-up of the randomized TWENTE trial.

OBJECTIVES The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. BACKGROUND Only limited long-term follow-up ...

متن کامل

The twelve-month outcome of biolimus eluting stent with biodegradable polymer compared with an everolimus eluting stent with durable polymer.

INTRODUCTION Drug-eluting stents (DES) have significantly decreased the need for repeat coronary revascularization but concerns remain regarding the safety of first and second generation DES. We compared the safety and efficacy of a biolimus-eluting stent (with biodegradable polymer) with an everolimus-eluting stent (with durable polymer) one. METHODS We performed a randomized trial to compar...

متن کامل

A randomized controlled trial in second-generation zotarolimus-eluting Resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial.

OBJECTIVES The aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up. BACKGROUND Only 1 randomized trial previously compared these stents. METHODS This investigator-initiated, p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2009