A general dual-bolus approach for high resolution quantitative DCE-MRI
نویسندگان
چکیده
Introduction: Accurate measurement of the arterial input function (AIF), essential for quantitative dynamic contrast-enhanced (DCE) MRI, is challenging due to the rapidly-changing high concentration of contrast agent during a bolus injection, particularly during the first pass peak. Temporal undersampling, inflow of unsaturated spins and signal saturation all have the potential to corrupt the measurement. Furthermore, imaging both the tissue of interest and a feeding vessel in the same volume constrains how well the different requirements for the AIF (high temporal resolution) and tissue uptake curve (high spatial resolution) are met. In this study, a dual-bolus technique is presented for accurate AIF measurement, applicable to high-resolution DCE-MRI of tissue uptake in any organ. A low-dose prebolus was used for AIF measurement, a technique first proposed to reduce signal saturation in quantitative myocardial perfusion imaging [1] that has also been applied in the lung [2]. The prebolus was scaled to estimate the AIF for a second, high-dose injection, for which the protocol can be tailored for monitoring tissue uptake only. A 3D TRICKS (Time Resolved Imaging of Contrast Kinetics) sequence [3] was incorporated for rapid sampling of the relatively low spatial frequencies present in an AIF. Results presented here demonstrate that the proposed technique can capture even the rapid circulation kinetics of a rabbit, and that the scaled prebolus AIF is equivalent to the AIF from a high-dose injection Methods: MR imaging was performed at 1.5 T (Signa EXCITE TwinSpeed; GE Healthcare, Milwaukee, WI, USA) on 5 New Zealand white rabbits (2.9-3.4 kg) using a transmit/receive knee coil. Anaesthesia was induced and maintained with 5 % and 2 ± 0.2 % isoflurane, respectively, in 100 % oxygen using a face mask. Contrast agent (Gd-DTPA – Magnevist, Berlex Canada, Lachine, Canada) was administered through the ear vein using a power injector (Spectris Solaris, Medrad, Warrendale, PA), adapted for use with rabbits. A double dose of contrast agent was used (0.2 mmol kg), split into 20 % for the prebolus and 80 % for the main bolus. In each case Gd-DTPA was diluted with saline to the same volume as the original double dose (0.4 ml kg). Contrast was injected at a rate of 0.5 ml s, followed by a 2 ml saline chaser. The study was approved by our institutional animal care committee. The aorta was imaged in the sagittal plane, with the volume positioned to have one slice running down the centre of the caudal portion of the vessel, using an oblique volume if necessary. Acquisitions were location-matched for the two injections. For both the prebolus and main bolus, a 3D TRICKS acquisition was used with the following parameters: FOV 18 cm, 70 % phase FOV, 10 reconstructed slices (overcontiguous), 3 mm slice thickness, in-plane matrix 90 x 90, 0.75 NEX. The prebolus acquisition used a 20° flip angle to increase signal to noise ratio for the low dose, whilst the main bolus used 40° to increase signal-to-noise ratio and avoid signal saturation. Repetition and echo times were TR / TE = 2.94-3.14 / 1.33-1.36 ms, depending on slice obliquing. Temporal resolution was ~0.4 s. Baseline signal intensities were acquired before the prebolus injection for both the 20° and 40° sequences, (56 phases). The passage of each bolus was imaged by acquiring the TRICKS sequence twice in quick succession (112 phases total). A period of 15 min elapsed between the prebolus and main bolus injection. AIFs were extracted from the image slice that lay in the centre of the aorta (to minimise partial volume effects), in the caudal portion of the vessel (to minimise inflow effects). For the main bolus images, signal intensity-time curves were plotted for a grid of 9 x 9 voxels centred over the vessel, and converted to ΔR1-time curves using an assumed baseline T1 for rabbit blood of 1270 ms [4], the standard spoiled gradient echo signal equation, and a linear relationship between ΔR1 and contrast agent concentration. Voxels were selected from the grid for inclusion in the AIF if the baseline signal intensity and peak height were similar to that in the centre of the vessel. The same voxels were chosen for the prebolus AIF so that any partial volume effects would be consistent between the two curves. Chosen voxels were averaged together to form the prebolus and main bolus AIFs, and the prebolus AIF was scaled by a factor of four for comparison with the main bolus. Results: A sample TRICKS image is shown in Fig. 1, clearly demonstrating the aorta during passage of the main bolus peak. The arrow shows the position of the region of interest for the AIF. Fig. 2 shows the agreement between the scaled prebolus and main bolus AIFs for each animal. Discussion: This study shows that the AIF measured from the prebolus is equivalent to that measured during the main bolus injection. Using the prebolus to estimate the AIF allows the protocols for the two injections to be tailored to the unique requirements of the AIF and tissue uptake curve. The AIF can be imaged in-plane (reducing inflow effects), without signal saturation and with good definition of the first-pass peak due to rapid temporal sampling. For the main bolus injection used to monitor tissue uptake, sampling can be slower [5] to allow high spatial resolution, a higher contrast dose could be employed if necessary to achieve adequate signal, and the feeding vessel need not be included in the field of view. Conclusion: The dual-bolus protocol described here allows measurement of a high temporal resolution AIF, free from signal saturation effects and with minimised inflow and partial volume effects. Separate acquisition of the AIF allows the contrast agent uptake in the tissue of interest to be imaged at high spatial resolution without inclusion of a feeding vessel. Acknowledgements: We thank Ruth Weiss and Garry Detzler for technical assistance with scanning, and Riad Alameddine for advice on power injector setup. Grant Sponsors: NSERC and CIHR. References: [1] Kostler et al MRM 2004;52:296. [2] Oeschner et al JMRI 2009;30:104. [3] Korosec et al MRM 1996;36:345. [4] Cheng JMRI 2007;25:1073. [5] Henderson et al MRI 1998;16:1057 Figure 1 – TRICKS image at the main bolus peak. Arrow shows level of ROI 0 50 100 0 5 10
منابع مشابه
A population-based AIF for quantitative DCE-MRI of the rat abdomen acquired using dynamic high temporally and spatially resolved CT
Introduction Quantitative dynamic contrast-enhanced (DCE) MRI is a widely used technique for studies of tumor progress and viability. The method requires knowledge of the arterial plasma concentration of the contrast agent (CA) in the vessels feeding the tissue of interest. This arterial input function (AIF) must be sampled with a high temporal and spatial resolution to enable stable pharmacoki...
متن کاملHybrid Reference Tissue Calibrated Dual-Bolus 3D Quantitative Dynamic Contrast-Enhanced MRI in a Rabbit VX2 Tumor Model
Introduction: Dynamic contrast-enhanced (DCE) MRI can be used to quantitatively measure pharmacokinetic parameters that indicate tumor angiogenesis and perfusion. The ability of quantitative DCE-MRI to generate physiological parameter maps has important implications in staging tumors and in evaluating the cancer therapeutic response. The purpose of this study was to develop an innovative hybrid...
متن کاملDynamic Contrast-Enhanced MRI of Mouse Liver: A Feasibility Study Using a Dual-Input Two-Compartment Tracer Kinetic Model
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been widely applied to evaluate microcirculatory parameters in clinical settings. However, pre-clinical studies involving DCE-MRI of small animals remain challenging with the requirement for high spatial and temporal resolution for quantitative tracer kinetic analysis. This study illustrates the feasibility of applying a high te...
متن کامل3D Dynamic Contrast-Enhanced Using Undersampled Golden-Radial Phase Encoding
INTRODUCTION: 3D Time-Resolved Dynamic Contrast Enhanced MRI (DCE-MRI) is an important tool to depict anatomic and dynamic information (bolus pass) of thoracic vessels. The current limitation of this application is the requirement of both high spatial and temporal resolution. Several methods have been proposed to overcome this problem [1-3], however, these techniques usually need an accurate ti...
متن کاملComparison between MRI Blood-to-Brain Transfer Rate Constants from Individual MRI and Population Averaged Quantitative Autoradiographic Arterial Input Functions
Introduction: An arterial input function (AIF), plasma concentration versus time curve, for an MR contrast agent (MRCA) is used to estimate the blood–brain barrier (BBB) permeability of microvessels and several other vascular related parameters. In dynamic contrast-enhanced MRI (DCE-MRI), an intravenous step-down infusion (SDI) procedure that maintains a constant gadolinium-diethylenetriaminepe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009