Matrix-assisted laser desorption/ionization mass spectrometric analysis of aliphatic biodegradable photoluminescent polymers using new ionic liquid matrices.
نویسندگان
چکیده
In this study, two novel ionic liquid matrices (ILMs), N,N-diisopropylethylammonium 3-oxocoumarate and N,N-diisopropylethylammonium dihydroxymonooxoacetophenoate, were tested for the structural elucidation of recently developed aliphatic biodegradable polymers by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The polymers, formed by a condensation reaction of three components, citric acid, octane diol, and an amino acid, are fluorescent, but the exact mechanism behind their luminescent properties has not been fully elucidated. In the original studies, which introduced the polymer class (J. Yang et al., Proc. Natl. Acad. Sci. USA 2009, 106, 10086-10091), a hyper-conjugated cyclic structure was proposed as the source for the photoluminescent behavior. With the use of the two new ILMs, we present evidence that supports the presence of the proposed cyclization product. In addition, the new ILMs, when compared with a previously established ILM, N,N-diisopropylethylammonium α-cyano-3-hydroxycinnimate, provided similar signal intensities and maintained similar spectral profiles. This research also established that the new ILMs provided good spot-to-spot reproducibility and high ionization efficiency compared with corresponding crystalline matrix preparations. Many polymer features revealed through the use of the ILMs could not be observed with crystalline matrices. Ultimately, the new ILMs highlighted the composition of the synthetic polymers, as well as the loss of water that was expected for the formation of the proposed cyclic structure on the polymer backbone.
منابع مشابه
Matrix-assisted laser desorption/ionization mass spectrometric analysis of uncomplexed highly sulfated oligosaccharides using ionic liquid matrices.
Direct UV matrix-assisted laser desorption/ionization (MALDI) mass spectrometric analysis of uncomplexed, underivatized, highly sulfated oligosaccharides has been carried out using ionic liquids as matrices. Under conventionally used MALDI time-of-flight experimental conditions, uncomplexed polysulfated oligosaccharides do not produce any signal. We report that 1-methylimidazolium alpha-cyano-4...
متن کاملIonic liquids as matrices in microfluidic sample deposition for high-mass matrix- assisted laser desorption/ionization mass spectrometry.
Sample preparation for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) via a microfluidic deposition device using ionic liquid matrices addresses several problems of standard protocols with crystalline matrices, such as the heterogeneity of sample spots due to the co-crystallization of sample and matrix and the limited capability for high-throughput analysis. Since ioni...
متن کاملIonic liquid matrix for direct UV-MALDI-TOF-MS analysis of dermatan sulfate and chondroitin sulfate oligosaccharides.
Polyanionic oligosaccharides such as dermatan sulfate (DS) and chondroitin sulfate (CS) exhibit poor ionization efficiencies and tend to undergo thermal fragmentation through the loss of SO(3) under conventional ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI) conditions. A new ionic liquid matrix (ILM), a guanidinium salt of alpha-cyano-4-hydroxycinnamic acid, facilitates dir...
متن کاملIonic Liquids Matrices for Laser Assisted Desorption/Ionization Mass Spectrometry
This review article discussed application of ionic liquids as matrices (ILMs) for mass spectrometry (MS). ILMs were applied for matrix assisted laser desorption/ionization, (ILMALDI-MS), electrospray ionization (ILMs-ESI-MS) and desorption corona beam ionization (DCBI-MS). Ionic liquids matrices provided several advantages such as low vapor pressure, have high stability for storage and under va...
متن کاملDesorption Electrospray Ionization (DESI)
A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The resulting mass spectra are similar to normal ESI mass ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 25 9 شماره
صفحات -
تاریخ انتشار 2011