Clinical Implementation of Non - Physical Wedges 1999 AAPM Refresher Course

نویسندگان

  • Sha X. Chang
  • John P. Gibbons
چکیده

A non-physical wedge generates a spatial dose distribution similar to that produced by a physical wedge without a physical filter in the photon beam. Instead, an exponential fluence profile is produced via motion of one of the collimating jaws. Proposed in the late 1970s, nonphysical wedges have been implemented on both Varian and Siemens’ accelerators as the Varian Dynamic Wedge (DW) and Siemens Virtual Wedge (VW). Recently, Varian has introduced the Enhanced Dynamic Wedge (EDW) to add functionality to this modality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refresher course for teaching cardiovascular physiology.

This report presents highlights of a refresher course presented at Experimental Biology '99 on Saturday, April 17, 1999, in Washington, District of Columbia.

متن کامل

Design, implementation and evaluation of short-term electronic training courses for medical students to prepare for participation in clinical competency tests of general medicine

Abstract Design, implementation and evaluation of short-term electronic training courses for medical students to prepare for participation in clinical competency tests of general medicine Introduction: Due to the need to teach practical skills to students and provide the opportunity to repeat the practice of these skills during the internship and after the clinical competency test and the b...

متن کامل

Monte Carlo study on beam hardening effect of physical wedges

Background: Physical wedges are still widely used as beam modifiers in external beam radiotherapy. However the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. The aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...

متن کامل

WHERE IS HERE, WHAT AM I?DESIGNING, IMPLEMENTATION AND EVALUATION OF AN INTRODUCTION TO CLINICAL CLERKSHIP COURSE FOR MEDICAL STUDENTS*

Introduction: Clinical education environment is unfamiliar to students, comparing to previous learning environments. It seems that designing a program to match actual needs of students for adopting to this new environment may lead to more cooperation of them and improve educational outcomes: Method: Learning needs for such a course were assessed according to viewpoints of both medical studen...

متن کامل

A Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999