Observation of optical Smith-Purcell radiation at an electron beam energy of 855 MeV.

نویسندگان

  • G Kube
  • H Backe
  • H Euteneuer
  • A Grendel
  • F Hagenbuck
  • H Hartmann
  • K H Kaiser
  • W Lauth
  • H Schöpe
  • G Wagner
  • Th Walcher
  • M Kretzschmar
چکیده

Smith-Purcell radiation, generated when a beam of charged particles passes close to the surface of a diffraction grating, has been studied in the visible spectral range at wavelengths of 360 and 546 nm with the low emittance 855 MeV electron beam of the Mainz Microtron MAMI. The beam focused to a spot size of 4 microm (full width at half maximum) passed over optical diffraction gratings of echelle profiles with blaze angles of 0.8 degrees, 17.27 degrees, and 41.12 degrees and grating periods of 0.833 and 9.09 microm. Taking advantage of the specific emission characteristics of Smith-Purcell radiation a clear separation from background components, such as diffracted synchrotron radiation from upstream beam optical elements and transition radiation, was possible. The intensity scales with a modified Bessel function of the first kind as a function of the distance between electron beam and grating surface. Experimental radiation factors have been determined and compared with calculations on the basis of Van den Berg's theory [P.M. Van den Berg, J. Opt. Soc. Am. 63, 689 (1973)]. Fair agreement has been found for gratings with large blaze angles while the measurement with the shallow grating (blaze angle 0.8 degrees ) is at variance with this theory. Finally, the optimal operational parameters of a Smith-Purcell radiation source in view of already existing powerful undulator sources are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

N ov 2 00 3 Experimental investigation of coherent Smith - Purcell radiation from a ” flat ” grating

Using the pre-bunched electron beam of 5-MeV linear accelerator the coherent Smith-Purcell radiation (CSPR) from a flat periodic target (made of conductive layers separated by dielectric gaps) in millimeter wavelength region has been investigated. The angular distribution of this radiation was measured with a narrow-band detector and experimental data agree with our theoretical calculations for...

متن کامل

Forward Diffracted Parametric X Radiation From a Thick Tungsten Single Crystal at 855 MeV Electron Energy

Features of forward diffracted Parametric X-Radiation (PXR) were investigated at experiments with the 855 MeV electron beam of the Mainz Microtron MAMI employing a 410 μm thick tungsten single crystal. Virtual photons from the electron field are diffracted by the (101̄) plane at a Bragg angle of 3.977. Forward emitted radiation was analyzed at an energy of 40 keV with the (111) lattice planes of...

متن کامل

Physical characteristics of electron beam from conventional and beam shaper IOERT applicator: A comparison study

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

متن کامل

Investigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic

Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...

متن کامل

Investigating the Effects of Cut-Out Shield on High-Energy Electron Fields Using MAGIC Normoxic Polymer Gel

Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 65 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2002