Simultaneous determination of paracetamol and caffeine by flow injection-solid phase spectrometry using C18 silica gel as a sensing support.

نویسندگان

  • P Ortega-Barrales
  • R Padilla-Weigand
  • A Molina-Díaz
چکیده

A continuous and simple UV-photometric flow-through biparameter-sensing device has been developed for the simultaneous determination of paracetamol and caffeine at 275 nm. The sensor is based on temporary sequentiation in the arrival of the analytes to the sensing zone by on-line separation using C18 bonded phase beads (the same as that used in the sensing zone) placed into a minicolumn just before the flow cell. The sample containing these compounds is injected into the carrier solution; paracetamol is determined first because it passes through the minicolumn, while caffeine is strongly retained in it. Then, caffeine is conveniently eluted from the precolumn and develops its transitory signal. Using 200 microl of a sample and deionized water as a carrier, the analytical signal showed a very good linearity in the ranges of 10-160 microg ml(-1) and 3.5-50 microg ml(-1) with detection limits of 0.75 and 0.56 microg ml(-1) for paracetamol and caffeine, respectively. If deionized water with the pH adjusted at 12 was used as a carrier solution, these parameters were 25-400 and 4-55 microg ml(-1) with 2.0 and 0.50 microg ml(-1) as the detection limits, respectively. The biparameter optosensor was satisfactorily applied to the simultaneous determination of these two analytes in pharmaceuticals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Least-squares support vector machine and its application in the simultaneous quantitative spectrophotometric determination of pharmaceutical ternary mixture

This paper proposes the least-squares support vector machine (LS-SVM) as an intelligent method applied on absorption spectra for the simultaneous determination of paracetamol (PCT), caffeine (CAF) and ibuprofen (IB) in Novafen. The signal to noise ratio (S/N) increased. Also, In the LS - SVM model, Kernel parameter (σ2) and capacity factor (C) were optimized. Excellent prediction was shown usin...

متن کامل

Simultaneous determination of caffeine, ergotamine, and metamizol in solid pharmaceutical formulation by HPTLC-UV-FLD with mass confirmation by online HPTLC-ESI-MS.

A new high-throughput method is developed to quantify caffeine, ergotamine, and metamizol in a solid pharmaceutical formulation. After dissolution, the compounds are separated on silica gel 60 F(254) high-performance thin-layer chromatography (HPTLC) plates with ethyl acetate-methanol-ammonia 90:15:1 (v/v/v) as the mobile phase. Detection is performed by UV absorption at 274 nm for caffeine and...

متن کامل

Simultaneous determination of paracetamol, 4-Aminophenol, 4-Chloroacetanilid, Benzyl alcohol,Benzaldehyde and EDTA by HPLC methodin paracetamol injection ampoule

Paracetamol that is known as acetaminophen have the most consume as an analgesic and antipyreticdrug in the world. That is formulated in single compound or mixture at many forms such astablets, syrups, suspensions and drops. The last form is intravenous injections. Paracetamol derivedfrom 4-minophenol which is synthesized by acylated the P-acetaminophenol and acetic anhydride.4-aminophenol is t...

متن کامل

Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...

متن کامل

Simultaneous flow-injection solid-phase fluorometric determination of thiabendazole and metsulfuron methyl using photochemical derivatization.

A flow-through optosensor implemented with photochemically induced fluorescence (PIF) is reported for the simultaneous determination of thiabendazole (TBZ) and metsulfuron methyl (MET). TBZ is determined by measuring its native fluorescence once retained on the solid support filling the flow-cell of a FI-system. On the other hand, a strongly fluorescent photoproduct from MET is generated on-lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 2002