Influence of reagent formulation on mRNA quantification by RT-PCR using imported external standard curves.
نویسندگان
چکیده
Use of an imported external standard curve is common in real-time quantitative RT-PCR. Two practical strategies for long-term experiments include importing a grand mean standard curve to all accumulated runs or using daily imported standard curves, fixing the slope at the beginning of the experiment and calibrating successive runs with curves generated from this imported slope, adding a single standard that registers the variation in the y-intercept. This study determines the influence that a change in reagent lots has on these two calibration approaches when determining mRNA copy numbers of the ornithine decarboxylase and porphobilinogen deaminase genes. Two sets of determinations were run with the use of lot A and lot B. A marked decrease in the crossing points (Cp) in the standards for both genes at all concentration levels was observed with the change in lots. A grand mean standard curve was generated for each gene and each set and comparisons between the sets were performed. Statistically significant differences were found with respect to the y-intercept but not the slope, suggesting that the change of reagent lot affected the detection sensitivity but not the efficiency of the reaction. The excellent correlation coefficients obtained for these curves for each gene were not achieved when overall data from both sets were combined to generate an overall grand mean standard curve. We conclude that when faced with a change of RT-PCR reagent lot that will affect the detection sensitivity of the method, samples should be calculated with either the daily imported standard curves or with the respective grand mean standard curve for each lot.
منابع مشابه
Quantitative real-time RT-PCR using hybridization probes and imported standard curves for cytokine gene expression analysis.
Quantitative real-time or kinetic RT-PCR is increasingly used for the quantification of specific mRNA targets, especially in clinical applications. To quantify the mRNA of cytokines and their receptors, which play important roles in the pathogenesis of autoimmune diseases such as multiple sclerosis, we have developed quantitative two-step RT-PCR assays for IL-4, IL-4R, IFN-gamma, IFN-beta, and ...
متن کاملAbsolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR
The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...
متن کاملQuantification of rat pre-pro-thyrotropin releasing hormone (TRH) mRNA by reverse transcription-polymerase chain reaction using external and internal standardisation.
We have developed a quantitative reverse transcription polymerase chain reaction (RT-PCR) method, using both internal and external standardisation, to quantitate fg amounts of pre-pro-thyrotropin releasing hormone (pre-pro-TRH) mRNA in the paraventricular nucleus (PVN) of individual laboratory rats. A constant amount of internal standard is coamplified with both the cDNA of each unknown specime...
متن کاملExpression of growth hormone gene during early development of Siberian sturgeon (Acipenser baerii)
The mRNA expression of growth hormone (GH) gene in early development stages of Siberian sturgeon was investigated using RT-PCR method. Samples were collected from unfertilized eggs up to 50 days post hatched (dph) larvae in 11 different times. Ribosomal protein L6 (RPL6) transcripts were used as the internal standard during quantification of GH mRNA expression. The results showed that the GH mR...
متن کاملAn internal reference technique for accurately quantifying specific mRNAs by real-time PCR with application to the tceA reductive dehalogenase gene.
The accuracy of mRNA quantification by reverse transcription (RT) in conjunction with real-time PCR (qPCR) is limited by mRNA losses during sample preparation (cell lysis, RNA isolation, and DNA removal) and by inefficiencies in reverse transcription. To control for these losses and inefficiencies, a technique was developed that utilizes an exogenous internal reference mRNA (ref mRNA) along wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta biochimica Polonica
دوره 52 4 شماره
صفحات -
تاریخ انتشار 2005