Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.

نویسندگان

  • Jung-Sun Kim
  • Ik-Kyung Jang
  • Chunyu Fan
  • Tae Hoon Kim
  • Jin-Sun Kim
  • Sang Min Park
  • Eui-Young Choi
  • Sang Hak Lee
  • Young-Guk Ko
  • Donghoon Choi
  • Myeong-Ki Hong
  • Yangsoo Jang
چکیده

OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR OCT (Evaluation in 3 Months Duration of Neointimal Coverage after Zotarolimus-Eluting Stent Implantation by Optical Coherence Tomography) trial is a prospective, single-center study evaluating vascular healing patterns with optical coherence tomography (OCT) at 3 months after stent implantation. A total of 31 ZES in 30 patients underwent serial OCT at immediate post-intervention and 3 months. Neointimal growth and malapposition were analyzed at each stent strut of cross-sectional OCT images with 0.5-mm intervals. RESULTS The incidence of malapposition at post-intervention and 3 months was 6.0% and 0.2%, respectively. However, late acquired malapposition was not detected at 3 months. Of 31 stents, 27 stents (87.1%) were covered completely with neointima, but the remaining 4 stents had 2 (0.8%), 4 (0.9%), 4 (1.2%), and 6 (1.4%) uncovered struts. Overall mean percentage of covered stent struts was 99.9 +/- 0.4%. This finding was consistent among groups with acute coronary syndrome and stable angina pectoris (99.9 +/- 0.3% vs. 99.9 +/- 0.4%, p = 0.92). Intracoronary thrombus was documented in 1 stent (3.2%) among 31 stents. CONCLUSIONS Most of the stent struts were covered with neointima, and late acquired malapposition was not found at 3 months after ZES implantation. Therefore, the current study demonstrated that ZES might have a favorable in vivo vascular response at 3 months after stent implantation. (Evaluation of Zotarolimus Eluting Stent at 3 Months Using Optical Coherence Tomography [ENDEAVOR OCT]; NCT00815139).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents

OBJECTIVE To evaluate the vascular response at 9 months after zotarolimus-eluting stent (ZES; Endeavor) implantation using optical coherence tomography (OCT). These findings were compared with those after implantation of a sirolimus-eluting stent (SES; Cypher Select). DESIGN Cross-sectional observational study with prospective OCT registry. SETTING Nine months after ZES or SES implantation....

متن کامل

Quantitative and qualitative changes in DES-related neointimal tissue based on serial OCT.

OBJECTIVES The study evaluated serial quantitative and qualitative changes in vascular responses to drug-eluting stents (DES) using optical coherence tomography (OCT). BACKGROUND Serial changes in stent strut coverage and neointima characteristics in DES-treated lesions have not been sufficiently investigated using OCT. METHODS Serial OCT was performed in 72 patients with 76 DES-treated les...

متن کامل

Comparison of Neointimal Tissue Characteristics Between Bare-metal and Second-generation Drug-eluting Stents Nine Months after Implantation in Patients with ST-segment Elevation Myocardial Infarction

Background: Neointimal tissue characteristics after implantation of stents are related to late/ very late stent thrombosis and/ or restenosis of target lesion. However, the difference of them has not been fully elucidated among bare-metal stents (BMS) and second-generation drug-eluting stents (DES). Methods: The present study uses optical coherence tomography (OCT) to compare neointimal tissue ...

متن کامل

Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.

Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...

متن کامل

The relationship between re-endothelialization and endothelial function after DES implantation: Comparison between paclitaxcel eluting stent and zotarolims eluting stent

BACKGROUND Several studies have reported re-endothelialization and endothelial function after drug-eluting stent (DES) implantation; however, the relationship between re-endothelialization and endothelial function after DES implantation has not been investigated yet. METHODS A total of 14 patients underwent evaluation of re-endothelialization by optical coherence tomography (OCT) and endothel...