The impact of different positions and thoracial restrains on respiratory induced cardiac motion.

نویسندگان

  • Steffen Huber
  • Axel Bornstedt
  • Bernhard Schnackenburg
  • Ingo Paetsch
  • Eckart Fleck
  • Eike Nagel
چکیده

One of the limiting factors for high resolution magnetic resonance coronary angiography (MRCA) is the motion of the heart during breathing. Current approaches use mainly motion correction in one dimension. We aimed to determine the relation between diaphragmatic motion and cardiac motion as well as the potential influence from external restraints reducing thoracical anterior posterior (AP) motion. Four real time navigators were used to collect motion parameters, diaphragmatic cranio-caudal, cardiac cranio-caudal, diaphragmatic anterior-posterior, and thoracical anterior-posterior. Measurements were performed in prone and supine position and supine position with a thorax restraint. In supine, the highest correlation was found between cranio-caudal diaphragmatic and cardiac motion (r2 = 0.71, slope = 0.26; p < 0.05). Prone positioning or external restraints led to significant changes of motion patterns, with a lower correlation between diaphragmatic and cardiac position. External manipulation of breathing by prone positioning or thoracical restraints leads to a less accurate prediction of cardiac position from assessment of diaphragmatic positions compared to standard supine positioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2006