Termination of Ventricular Tachycardia with Antitachycardia Pacing after Ineffective Shock Therapy in an ICD Recipient with Hypertrophic Cardiomyopathy
نویسندگان
چکیده
Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected.
منابع مشابه
An unusual ICD shock: What is the mechanism?
Case report A 48-year-old man with nonischemic dilated cardiomyopathy, left ventricular ejection fraction r35% status post dual-chamber ICD (Boston Scientific Energen, model E142) since September 2012, history of ventricular tachycardia with antitachycardia pacing (ATP) therapy, paroxysmal atrial fibrillation, and atrial tachycardia on beta-blocker therapy was seen in clinic following an ICD sh...
متن کاملThe tachycardia that outsmarted the SMART
A 57-year-old man presented with palpitations and shock delivery from his implantable cardioverter-defibrillator (ICD). He had a history of ischemic cardiomyopathy with an ejection fraction of 20%. One month prior to this presentation, he received a DX ICD (Iforia 5 VR-T DX, Biotronik SE & Co. KG) for primary prevention of sudden cardiac death. Two ventricular tachycardia (VT) zones (VT1 162–18...
متن کاملSeventh try's a charm: ventricular fibrillation terminated by the seventh shock.
A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...
متن کاملVentricular Fibrillation Terminated by the Seventh Shock
A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...
متن کاملShould catheter ablation be the preferred therapy for reducing ICD shocks?: Ventricular tachycardia ablation versus drugs for preventing ICD shocks: role of adjuvant antiarrhythmic drug therapy.
In 1980, Mirowski et al1 implanted the first implantable cardioverter-defibrillator (ICD) in a young female with recurrent ventricular fibrillation and provided an innovative approach to aborted sudden cardiac death (SCD). Although the ICD was considered a treatment of last resort during that incipient stage, subsequent years have witnessed prolific expansion of indications for ICD implantation...