Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI

نویسندگان

  • Laurent Bonnemains
  • Freddy Odille
  • Christophe Meyer
  • Gabriella Hossu
  • Jacques Felblinger
  • Pierre-André Vuissoz
  • Alberto Aliseda
چکیده

BACKGROUND During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein's model is used to project multiple cardiac cycles of variable lengths into a mean cycle. OBJECTIVE To assess the effect of Feinstein projection on temporal resolution of Cine-MRI. METHODS 1/The temporal errors during Feinstein's projection were computed in 306 cardiac cycles fully characterized by tissue Doppler imaging with 6-phase analysis (from a population of 7 children and young adults). 2/The effects of these temporal errors on tissue velocities were assessed by simulating typical tissue phase mapping acquisitions and reconstructions. 3/Myocardial velocities curves, extracted from high-resolution phase-contrast cine images, were compared for the 6 volunteers with lowest and highest heart rate variability, within a population of 36 young adults. RESULTS 1/The mean of temporal misalignments was 30 ms over the cardiac cycle but reached 60 ms during early diastole. 2/During phase contrast MRI simulation, early diastole velocity peaks were diminished by 6.1 cm/s leading to virtual disappearance of isovolumic relaxation peaks. 3/The smoothing and erasing of isovolumic relaxation peaks was confirmed on tissue phase mapping velocity curves, between subjects with low and high heart rate variability (p = 0.05). CONCLUSIONS Feinstein cardiac model creates temporal misalignments that impair high temporal resolution phase contrast cine imaging when beat-to-beat heart rate is changing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of subject-specific prediction of end-systolic time in MRI across a range of RR intervals

BACKGROUND Prediction of End-Systole time is of utmost importance for cardiac MRI to correctly associate acquired k-space lines during reconstruction of cine acquisitions. This prediction is usually based on the patient's heart rate using Weissler's formula, which was calibrated by linear regression within a population and cannot account for individual variability. OBJECTIVE We propose an aut...

متن کامل

4-dimensional, multiphase, steady-state imaging with contrast enhancement (MUSIC) in the heart; a feasibility study in children

PURPOSE To develop a technique for high resolution, four-dimensional (4D), multiphase, steady-state imaging with contrast enhancement (MUSIC) in children with complex congenital heart disease. METHODS Eight pediatric patients underwent cardiovascular MRI with controlled mechanical ventilation after ferumoxytol administration. Breath-held contrast-enhanced MRA (CE-MRA) was performed during the...

متن کامل

Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction.

Cardiac function has traditionally been evaluated using breath-hold cine acquisitions. However, there is a great need for free breathing techniques in patients who have difficulty in holding their breath. Real-time cardiac MRI is a valuable alternative to the traditional breath-hold imaging approach, but the real-time images are often inferior in spatial and temporal resolution. This article pr...

متن کامل

High resolution multislice imaging of the fetal heart using iGRASP and MOG

Background Multi-slice CINE MRI is an integral facet of postnatal cardiac examinations, but its application to the fetal heart is hampered by the lack of a fetal cardiac gating signal and the possibility of fetal motion. In this work, a method for reconstructing high spatial and temporal resolution multi-slice images of the fetal heart in a clinically acceptable scan time is presented. The prop...

متن کامل

High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.

Cine MRI is used for assessing cardiac function and flow and is typically based on a breath-held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real-time imaging may be used without breath holding or ECG triggering. However, despite the use of rapid imaging sequences and accelerated parallel imaging, real-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015