Experimental Study of Thermal Environment in a Room with Mixing Ventilation

نویسندگان

  • Dong - Mei Pan
  • Ming - Yin Chan
چکیده

This paper reports an experimental study on a sleeping thermal manikin in a room equipped with a mixing ventilation system. In the experimental work, heat loss from the sleeping thermal manikin was measured under different conditions. The supply air temperature was in a range of 17°C to 27°C. Apart from the heat loss of the sleeping thermal manikin, the velocity distributions and temperature distributions were also measured in the experiments for subsequent analysis. Keywords—Sleeping Environment, Mixing Ventilation System

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal comfort of the surgical staff in an operating theatre: a numerical study on laminar and mixing ventilation systems

The indoor air quality in an operating theatre affects both patient health and the well-being of the surgical team members. Health care facilities, and operating theatres in particular, require ventilation and air conditioning for thermal comfort and removal of contaminants. Although the patient undergoing surgery is given the highest priority, it is important to consider the comfort of surgica...

متن کامل

Thermal Modeling for Predication of Automobile Cabin Air Temperature

Thermal modeling of an automotive cabin was performed in this paper to predict the inside cabin air temperature. To implement this task, thermal and ventilation loads were estimated and the mass and energy balance conservation equations for dry air and water vapor with considering a new parameter (air circulation ratio) as well as the balance equations of internal components of a cabin were de...

متن کامل

Glazed Transitional Space as a Passive Heating System (Case Study: Glazed Loggias in Semi-Arid climate)

The environmental concern, ensuring comfort for occupants, pushed us to search for the impact of glazed loggia on thermal comfort of adjacent space in Cons tantine climate, having s trong climatic cons traints. An experimental s tudy is undertaken and described in this paper. Analysis of the in situ results is also discussed. This work shows that in winter glazed loggia benefit largely from sol...

متن کامل

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

The role of natural ventilation on reducing indoor radon concentration

Due to the increasing of closed ventilation systems used in buildings, the risk of indoor radon is increased day by day. In this study, we selected two sample rooms to calculate the radon emission coefficient from different levels, radon concentration measured when the natural ventilation was completely closed and compared with the analytical results. The results clearly show the difference in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012