0 v 1 2 6 O ct 1 99 8 Ultra Bright LED Light Injection Calibration System for MINOS

نویسندگان

  • B. Anderson
  • A. Anjomshoaa
  • P. Dervan
  • J. A. Lauber
  • J. Thomas
چکیده

We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The MINOS Light Injection Calibration System

A description is given of the light-injection calibration system that has been developed for the MINOS long-baseline neutrino oscillation experiment. The system is based upon pulsed blue LEDs monitored by PIN photodiodes. It is designed to measure non-linearities in the PMT gain curves, as well as monitoring any drifts in PMT gain, at the 1% level.

متن کامل

RTES-03 Interfaces.indd

[ B ur ns 20 07 ] B u rn s, A & W el lin gs , A C o n cu rr en t a n d R ea l-T im e Pr o gr am m in g in A d a, e d it io n C am b ri d ge U n iv er si ty P re ss 2 00 7 [ M o to ro la 19 96 ] M o to ro la Ti m e Pr o ce ss in g U n it R ef er en ce M an u al 1 99 6 p p . 1 -1 42 [ M o to ro la 20 00 ] M o to ro la M PC 56 5 & M PC 56 6 2 00 0 p p . 1 -1 31 2 [ P ea co ck 19 97 ] Pe ac o ck , ...

متن کامل

ar X iv : h ep - p h / 98 10 52 7 v 1 2 9 O ct 1 99 8 HIGHER - TWIST CONTRIBUTIONS IN EXCLUSIVE PROCESSES

Using the renormalon technique, we estimate higher-twist contributions in deeply virtual Compton scattering and in hard exclusive π 0 leptoproduction.

متن کامل

ar X iv : a st ro - p h / 98 05 07 7 v 1 6 M ay 1 99 8 Long - Term X - ray Variability in GX 354 – 0

We report for the first time the detection of long-term X-ray variability in the bright bulge source GX 354–0 (=4U 1728–34) observed with the All Sky Monitor (ASM) on board the Rossi X-Ray Timing Explorer (RXTE). The 2-year RXTE ASM database reveals significant power at ∼ 72 days. Similar behaviour was seen in the 6-year Ariel 5 ASM database, but at a period of ∼ 63 days. The timescales and lig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008