Miniplates and mini-implants: bone remodeling as their biological foundation1
نویسنده
چکیده
The tridimensional network formed by osteocytes controls bone design by coordinating cell activity on trabecular and cortical bone surfaces, especially osteoblasts and clasts. Miniplates and mini-implants provide anchorage, allowing all other orthodontic and orthopedic components, albeit afar, to deform and stimulate the network of osteocytes to command bone design remodeling upon "functional demand" established by force and its vectors. By means of transmission of forces, whether near or distant, based on anchorage provided by miniplates, it is possible to change the position, shape and size as well as the relationship established between the bones of the jaws. Understanding bone biology and the continuous remodeling of the skeleton allows the clinician to perform safe and accurate rehabilitation treatment of patients, thus increasing the possibilities and types of intervention procedures to be applied in order to restore patient's esthetics and function.
منابع مشابه
Mini-implants and miniplates generate sub-absolute and absolute anchorage
The functional demand imposed on bone promotes changes in the spatial properties of osteocytes as well as in their extensions uniformly distributed throughout the mineralized surface. Once spatial deformation is established, osteocytes create the need for structural adaptations that result in bone formation and resorption that happen to meet the functional demands. The endosteum and the periost...
متن کاملFully customized placement of orthodontic miniplates: a novel clinical technique
INTRODUCTION The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. METHODS In order to apply th...
متن کاملStability of connected mini-implants and miniplates for skeletal anchorage in orthodontics.
The aim of this study was to examine the primary stability of connected mini-implants and miniplates. Three different skeletal anchorage systems were investigated: (1) two 1.5 mm diameter cylindrical mini-implants connected with a 0.021 x 0.025 inch stainless steel (SS) wire, (2) two 1.6 mm diameter tapered mini-implants connected with a 0.021 x 0.025 inch SS wire, and (3) two 2.0 mm diameter c...
متن کاملA prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage.
PURPOSE The aim of this prospective clinical study was to assess the risk factors associated with failure of mini-implants used for orthodontic anchorage. MATERIALS AND METHODS A total of 140 mini-implants in 44 patients, including 48 miniplates and 92 freestanding miniscrews, were examined in the study. A variety of orthodontic loads were applied. The majority of implants were placed in the ...
متن کاملSurvival and failure rates of orthodontic temporary anchorage devices: a systematic review.
AIM The purpose of this study was to systematically review the literature on the survival rates of palatal implants, Onplants((R)), miniplates and mini screws. MATERIAL AND METHODS An electronic MEDLINE search supplemented by manual searching was conducted to identify randomized clinical trials, prospective and retrospective cohort studies on palatal implants, Onplants((R)), miniplates and mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 20 شماره
صفحات -
تاریخ انتشار 2015