Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System

نویسندگان

  • Cheng Wang
  • Xiangdong Wang
  • Zhou Long
  • Jing Yuan
  • Yueliang Qian
  • Jintao Li
چکیده

Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a gait analysis algorithm for estimating the temporal parameters of gait is presented. The algorithm fully uses the fusion of two feet footstep sound signals and includes three stages: footstep detection, heel-strike event and toe-on event detection, and calculation of gait temporal parameters. Experimental results show that with a total of 240 data sequences and 1732 steps collected using three different gait data collection strategies from 15 healthy subjects, the proposed system achieves an average 0.955 F1-measure for footstep detection, an average 94.52% accuracy rate for heel-strike detection and 94.25% accuracy rate for toe-on detection. Using these detection results, nine temporal related gait parameters are calculated and these parameters are consistent with their corresponding normal gait temporal parameters and labeled data calculation results. The results verify the effectiveness of our proposed system and algorithm for temporal gait parameter estimation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different methods for the estimation of gait temporal parameters using a single inertial sensor mounted on the lower trunk: application to elderly and hemiparetic subjects

The estimation of gait temporal parameters with wearable inertial measurement units (IMU) has been a research topic of interest in clinical gait analysis. Several methods, based on the use of a single IMU, have been proposed for their estimate, showing in most cases a sufficiently low number of missed and extra events and a satisfactory accuracy when applied to the gait of healthy subjects. In ...

متن کامل

Evaluation of the Performances of Two Wearable Systems for Gait Analysis: A Pilot Study

Introduction: Wearable sensor systems to perform human motion analysis are receiving increasing attention in different application fields. Among wearable sensors, inertial sensors have promising features. However, before they can be employed routinely in clinical applications, it is important to evaluate their reliability. Gait analysis was performed on one male volunteer: data were simultaneou...

متن کامل

Wearable sensors for gait analysis Comparison between a MIMUs system and a gold standard electromechanical system

Systems based on inertial sensors are increasingly used in motion analysis due to their low cost, portability and wearability. However, since accuracy is crucial in clinical gait analysis, it is important to assess it in new systems. The aim of this study is to compare the performances of a magnetic and inertial sensors system (MIMUs) to a gold standard, the electromechanical system STEP32. Res...

متن کامل

Design and development of ShrewdShoe, a smart pressure sensitive wearable platform

     This study introduces a wearable in-shoe system for real-time monitoring and measurement of the plantar pressure distribution of the foot using eleven sensing elements. The sensing elements utilized in ShrewdShoe have been designed in an innovative way, they are based on a barometric pressure sensor covered with a silicon coating. The presented sensing element has great linearity up to 300...

متن کامل

On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator

Gait analysis can provide valuable information on a person's condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016