Performance of 7T μMRI-Based Virtual Bone Biopsy for Structural and Mechanical Analysis at the Distal Tibia

نویسندگان

  • Y. A. Bhagat
  • C. S. Rajapakse
  • J. H. Love
  • M. J. Wald
  • J. F. Magland
  • A. C. Wright
  • H. K. Song
  • F. W. Wehrli
چکیده

EI and D) Ezz (axial stiffness) showing that means are significantly (p<0.001) different for many pair-wise comparisons (One-way ANOVA). Table 1: Means, CV and ICC for parameters relaying scale, topology and elasticity (GPa) in 5 subjects. Mechanical Anisotropy, MA= 2Ezz/(Exx+Eyy) Figure 1: Representative axial FSE-OSC images of a healthy 36year-old male subject across the 3 exams. 3D rendered skeletonized virtual cores ((69.5 μm) voxels) visually illustrate similarity: surface voxels (gray), surface edges (red), curve voxels (blue) and small plate perforations (green arrow). Performance of 7T μMRI-Based Virtual Bone Biopsy for Structural and Mechanical Analysis at the Distal Tibia

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of two spin-echo sequences for quantitative structure analysis of trabecular bone

Introduction: The susceptibility difference between bone and bone marrow promotes the use of spin echo-based sequences for high resolution magnetic resonance imaging (μMRI) of trabecular bone (TB) [1], particularly for B0>1.5T. At ultra high field strengths, specific absorption rate (SAR) limits for patient safety are breached by the fast large-angle spin-echo (FLASE) pulse sequence. Fast spin ...

متن کامل

Combined implications of bone′s structural and material impairment following renal transplantation assessed by μMRI based finite-element modeling

INTRODUCTION: High-resolution magnetic resonance imaging (μMRI) based micro-finite-element (μFE) modeling at peripheral sites is emerging as an attractive means to assess short-term alterations in bone’s mechanical competence caused by disease or in response to intervention [1, 2]. In this approach, subject-specific bone’s 3D micro-architecture derived from in-vivo μMRI is taken as input to a f...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009