Magnetic resonance microscopy of chemically fixed human embryos at high spatial resolution.
نویسندگان
چکیده
We acquired magnetic resonance (MR) microscopic images of chemically fixed human embryos of Carnegie stages 16 to 22 with a large image matrix (256 × 256 × 512) using an MR microscope that we developed with a 9.4-tesla vertical wide-bore superconducting magnet and a dual-channel receiver system to extend the dynamic range of the MR signal. The images showed clear anatomical structures at spatial resolutions of (40 µm)(3) to (60 µm)(3). We concluded that the experimental technique we developed will aid construction of the next anatomical database of the collection of chemically fixed human embryos.
منابع مشابه
Improving Brain Magnetic Resonance Image (MRI) Segmentation via a Novel Algorithm based on Genetic and Regional Growth
Background:Â Regarding the importance of right diagnosis in medical applications, various methods have been exploited for processing medical images solar. The method of segmentation is used to analyze anal to miscall structures in medical imaging.Objective:Â This study describes a new method for brain Magnetic Resonance Image (MRI) segmentation via a novel algorithm based on genetic and regiona...
متن کاملMagnetic resonance imaging of embryonic and fetal development in model systems.
We give an overview of the applications and methods of high-resolution anatomical magnetic resonance imaging (MRI) in the study of embryonic and fetal development in animal models. Challenges associated with performing in utero studies are described. Recent in utero images in mouse and in nonhuman primates are presented. Results using magnetic resonance microscopy in fixed mouse embryos and in ...
متن کاملLarge matrix acquisition of a chemically fixed human embryo for construction of a 3D anatomical database
INTRODUCTION Kyoto University has a large collection of chemically fixed human embryos (~50,000) collected since 1961 [1]. To construct their 3D anatomical database, 3D MR microscopic images of about 1,200 chemically fixed human embryos from Carnegie Stage (CS) 13 (28-32days) to 23 (56-60 days) were acquired with a 128×128×256 image matrix in a 2.35 T magnetic field [2]. In 2005, 3D MR images o...
متن کاملDiffusion MR Microscopy of Cortical Development in the Mouse Embryo.
Cortical development in the mouse embryo involves complex changes in the microstructure of the telencephalic wall, which are challenging to examine using three-dimensional (3D) imaging techniques. In this study, high-resolution 3D diffusion magnetic resonance (dMR) microscopy of the embryonic mouse cortex is presented. Using diffusion-weighted gradient- and spin-echo based acquisition, dMR micr...
متن کاملMultimodal imaging of human cerebellum - merging X-ray phase microtomography, magnetic resonance microscopy and histology
Imaging modalities including magnetic resonance imaging and X-ray computed tomography are established methods in daily clinical diagnosis of human brain. Clinical equipment does not provide sufficient spatial resolution to obtain morphological information on the cellular level, essential for applying minimally or non-invasive surgical interventions. Therefore, generic data with lateral sub-micr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine
دوره 14 2 شماره
صفحات -
تاریخ انتشار 2015