Improving Germanium Detector Resolution and Reliability

نویسندگان

  • Gregory N. Martin
  • K. Michael Yocum
  • James F. Colaresi
  • Harry S. Miley
چکیده

High purity germanium (HPGe) detectors used in radionuclide assay systems such as Radionuclide Aerosol Sampler/Analyzer (RASA) systems must operate unattended for long periods of time. Currently, the performance and reliability of commercially available large (~100%) HPGe detectors are acceptable for the majority of laboratory applications. However, for remote systems designed for nuclear detonation detection and analysis, improved performance and reliability are required. The goals of this research include improving germanium detector reliability and resolution performance by developing new surface passivation techniques coupled with a unique detector contact arrangement. A major reliability improvement would be realized if germanium detectors were made less sensitive to storage and operational environments by improving the film coating used to passivate and protect the intercontact surface. This research is the investigation of two surface film techniques for passivating HPGe detector surfaces. Wet chemically grown oxide films and sputtered film coatings will in turn be applied to two standard P-type HPGe coaxial detectors. Each coating will be characterized to determine their surface chemistry passivating qualities as well as their inherent noise contribution to the overall system noise. The resolution of a germanium detector is a function of electrical noise and the inherent resolution of the detector element. The electrical noise components which reduce the signal to noise ratio of a detector system are associated with detector leakage current, intercontact surface noise, contact noise and noise sources associated with preamplifier electronics. In particular, those noise components associated with the intercontact surface are leakage current and surface noise. We believe these two significant sources of noise can be reduced by using novel surface passivation techniques resulting in improved detector resolution. The techniques developed by this research will be applicable to new detectors and can also be applied as a retrofit to existing RASA units. This will improve the ability to obtain more sensitive and reliable detections of remote nuclear activity. 2008 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma and X-Ray Detection Introduction

DETECTOR RESOLUTION Resolution is a measure of the width (full width half max) of a single energy peak at a specific energy, either expressed in absolute keV (as with Germanium Detectors), or as a percentage of the energy at that point (Sodium Iodide Detectors). Better (lower FWHM value) resolution enables the system to more clearly separate the peaks within a spectrum. Figure 1.2 shows two spe...

متن کامل

Gamma and X-Ray Detection Introduction

DETECTOR RESOLUTION Resolution is a measure of the width (full width half max) of a single energy peak at a specific energy, either expressed in absolute keV (as with Germanium Detectors), or as a percentage of the energy at that point (Sodium Iodide Detectors). Better (lower FWHM value) resolution enables the system to more clearly separate the peaks within a spectrum. Figure 1.2 shows two spe...

متن کامل

Digital Timing Algorithm for High Purity Germanium Detectors

The next generation of γ-ray detector arrays will be composed of large volume high purity germanium (HPGE) detectors that are electronically segmented. These detectors will be able to track γ-rays as they Compton scatter within the crystal and between adjacent crystals, eliminating the need for Compton suppression detectors and improving angular resolution. The new arrays will have much higher ...

متن کامل

CHARACTERIZATION AND PERFORMANCE EVALUATION OF AN HPXe DETECTOR FOR NUCLEAR EXPLOSION MONITORING APPLICATIONS

Expanding missions in nuclear explosion monitoring (NEM) and nuclear security have highlighted the need for high-resolution ambient-temperature gamma detectors that can provide radionuclide-specific monitoring under demanding field conditions. Recent improvements in high-pressure xenon (HPXe) detectors indicate that this technology has potential to provide rugged, large volume ambient temperatu...

متن کامل

Efficiency for Close Geometries and Extended Sources of a P-type Germanium Detector with Low-energy Sensitivity

Typically, germanium detectors designed to have good sensitivity to low-energy photons and good efficiency at high energies are constructed from n-type crystals with a boron-implanted outer contact. These detectors usually exhibit inferior resolution and peak shape compared to ones made from p-type crystals. To overcome the resolution and peak-shape deficiencies, a new method of construction of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010