Depth Discrimination in Diffuse Optical Transmission Imaging by Planar Scanning Off-Axis Fibers: INITIAL Applications to Optical Mammography

نویسندگان

  • Jana M. Kainerstorfer
  • Yang Yu
  • Geethika Weliwitigoda
  • Pamela G. Anderson
  • Angelo Sassaroli
  • Sergio Fantini
چکیده

We present a method for depth discrimination in parallel-plate, transmission mode, diffuse optical imaging. The method is based on scanning a set of detector pairs, where the two detectors in each pair are separated by a distance δDi along direction δ D i within the x-y scanning plane. A given optical inhomogeneity appears shifted by αi δ D i (with 0≤ αi ≤1) in the images collected with the two detection fibers of the i-th pair. Such a spatial shift can be translated into a measurement of the depth z of the inhomogeneity, and the depth measurements based on each detector pair are combined into a specially designed weighted average. This depth assessment is demonstrated on tissue-like phantoms for simple inhomogeneities such as straight rods in single-rod or multiple-rod configurations, and for more complex curved structures which mimic blood vessels in the female breast. In these phantom tests, the method has recovered the depth of single inhomogeneities in the central position of the phantom to within 4 mm of their actual value, and within 7 mm for more superficial inhomogeneities, where the thickness of the phantom was 65 mm. The application of this method to more complex images, such as optical mammograms, requires a robust approach to identify corresponding structures in the images collected with the two detectors of a given pair. To this aim, we propose an approach based on the inner product of the skeleton images collected with the two detectors of each pair, and we present an application of this approach to optical in vivo images of the female breast. This depth discrimination method can enhance the spatial information content of 2D projection images of the breast by assessing the depth of detected structures, and by allowing for 3D localization of breast tumors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Off-axis chromatic scanning confocal electron microscopy for inelastic imaging with atomic resolution

The development of electron-optical techniques for geometric and chromatic aberration correction have significantly improved the spatial resolution of transmission electron microscopy (TEM) and enhanced its capability for chemical mapping [1]. In the present work, we develop an off-axis confocal mode in a scanning transmission electron microscope (STEM) which uses the intrinsic chromatic aberra...

متن کامل

Non-invasive optical estimate of tissue composition to differentiate malignant from benign breast lesions: A pilot study

Several techniques are being investigated as a complement to screening mammography, to reduce its false-positive rate, but results are still insufficient to draw conclusions. This initial study explores time domain diffuse optical imaging as an adjunct method to classify non-invasively malignant vs benign breast lesions. We estimated differences in tissue composition (oxy- and deoxyhemoglobin, ...

متن کامل

Fabrication of polymer-SiO2 nanocomposite optical fibers with a new method

At first step polymer optical fibers (POFs) are used in short distance for optical data transmissions. At second step SiO2 nanoparticles were prepared by sonochemical-assisted method. Silica nanoparticles were added to polymer matrix to prepare polymer based nanocomposites. Most of the POF applications are in the medical and electrical devices. There are several methods for fabrication of POFs,...

متن کامل

Engineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)

Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...

متن کامل

Optical depth sectioning in the aberration-corrected scanning transmission and scanning confocal electron microscope

The use of spherical aberration correctors in the scanning transmission electron microscope (STEM) has the effect of reducing the depth of field of the microscope, making three-dimensional imaging of a specimen possible by optical sectioning. Depth resolution can be improved further by placing aberration correctors and lenses pre and post specimen to achieve an imaging mode known as scanning co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013