Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants.

نویسندگان

  • Heinrich Koertke
  • Armin Zittermann
  • Otto Wagner
  • Songuel Secer
  • Alfonso Sciangula
  • Werner Saggau
  • Falk-Udo Sack
  • Jürgen Ennker
  • Jochen Cremer
  • Francesco Musumeci
  • Jan F Gummert
چکیده

AIM To study in patients performing international normalized ratio (INR) self-control the efficacy and safety of an INR target range of 1.6-2.1 for aortic valve replacement (AVR) and 2.0-2.5 for mitral valve replacement (MVR) or double valve replacement (DVR). METHODS AND RESULTS In total, 1304 patients undergoing AVR, 189 undergoing MVR and 78 undergoing DVR were randomly assigned to low-dose INR self-control (LOW group) (INR target range, AVR: 1.8-2.8; MVR/DVR: 2.5-3.5) or very low-dose INR self-control once a week (VLO group) and twice a week (VLT group) (INR target range, AVR: 1.6-2.1; MVR/DVR: 2.0-2.5), with electronically guided transfer of INR values. We compared grade III complications (major bleeding and thrombotic events; primary end-points) and overall mortality (secondary end-point) across the three treatment groups. FINDINGS Two-year freedom from bleedings in the LOW, VLO, and VLT groups was 96.3, 98.6, and 99.1%, respectively (P = 0.008). The corresponding values for thrombotic events were 99.0, 99.8, and 98.9%, respectively (P = 0.258). The risk-adjusted composite of grade III complications was in the per-protocol population (reference: LOW-dose group) as follows: hazard ratio = 0.307 (95% CI: 0.102-0.926; P = 0.036) for the VLO group and = 0.241 (95% CI: 0.070-0.836; P = 0.025) for the VLT group. The corresponding values of 2-year mortality were = 1.685 (95% CI: 0.473-5.996; P = 0.421) for the VLO group and = 4.70 (95% CI: 1.62-13.60; P = 0.004) for the VLT group. CONCLUSION Telemedicine-guided very low-dose INR self-control is comparable with low-dose INR in thrombotic risk, and is superior in bleeding risk. Weekly testing is sufficient. Given the small number of MVR and DVR patients, results are only valid for AVR patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INR self-management permits lower anticoagulation levels after mechanical heart valve replacement.

BACKGROUND The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of pr...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Aortic valve and aneurysms.

The aorta is the highway in the human circulation, and accordingly any functional or structural change is associated with severe symptoms or even a fatal outcome. The aortic valve is the door to the aorta and it opens up to 3 billion times in a lifetime. If not perfectly built by nature, e.g. in biscuspid valve disease or tricuspid valves with raphe, aortic sclerosis and eventually stenosis are...

متن کامل

Oral Anticoagulation after Mechanical Heart Valve Replacement: Low Intensity Regimen can Make the Difference

Despite continuous improvement in the field, the ideal prosthetic heart valve remains to be developed. Patients with mechanical prosthetic heart valves are at risk of thrombosis and systemic embolism. The incidence rate of these serious complications is significantly reduced by lifelong Oral Anticoagulant Therapy (OAC) vitamin K antagonist (VKA) therapy. Despite its undeniable benefits, VKA the...

متن کامل

Low-intensity oral anticoagulation plus low-dose aspirin versus high-intensity oral anticoagulation alone: a randomized trial in patients with mechanical prosthetic heart valves.

BACKGROUND Mechanical heart valve replacement requires lifelong anticoagulant treatment. Aspirin has proved useful in further reducing thromboembolic events when added to oral anticoagulants. However, increased (gastrointestinal) bleeding was observed at the doses previously tested for this combination in heart valve prostheses. METHODS We performed a prospective randomized trial to compare t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 36 21  شماره 

صفحات  -

تاریخ انتشار 2015