Experimental Study on the Performance of Twisted Capillary Tube

نویسنده

  • Amr O. Elsayed
چکیده

A novel capillary tube has been tested and evaluated experimentally in the refrigeration cycle of window type air conditioner. Three twisted capillary tubes have been demonstrated and evaluated to show the performance of these tubes and its ability in the depressurization process seeking for short capillary tube. The effect of twist angle and the number of twisted points on the refrigeration cycle performance have been investigated and compared with the performance of original straight capillary tube. Two twist angles and two different numbers of twisting points have been considered in this study. The results showed that the twist angle has a remarkable influence on the depressurization process and condensation temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Thermo-hydraulic Performance of Circular Tube Fitted with Center-cleared Twisted Tape Using CFD Modeling (RESEARCH NOTE)

The article presents a practical technique for enhancing thermo-hydraulic performance of a circular tube. In this way, numerical method focusing on laminar tubular flow is used to compare the effectiveness of utilizing center-cleared twisted tapes instead of typical shape of short width tapes. Numerical analysis represented that using both center-cleared and typical shape of twisted tapes, Re e...

متن کامل

Selection of Capillary Tube for Refrigeration System

Proper selection of capillary tube it is essential to study the effect of capillary tube geometry on the performance of refrigeration systems. The literature review is focused on the influence of geometrical parameters like tube length, diameter, coil pitch, number of twist and twisted angle on pressure drop and coefficient of performance (COP) of the system. These parameters can be optimized u...

متن کامل

Experimental Performance of Window Air Conditioner Using Alternative Refrigerants with Different Configurations of Capillary Tube A Review

This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capillary tubes (straight, twisted, coiled) in different length and diameter. they determined various parameters like coefficient of performance (COP),cooling capacity, energy efficien...

متن کامل

Energy Management and Process Improvement of Methanol Production

A heat exchanger network (HEN) for the process of methanol synthesis has been studied by combination of pinch design method and the application of “Twisted Tube” heat exchanger units as a new technology. The HEN is reconstructed based on the full utilization of maximum allowable pressure drops for the process hot and cold streams. An algorithm is developed to generate design procedure for twist...

متن کامل

Effect of Twisted Tape Baffles on Pressure Drop, Fluctuation and Expansion Ratios in gas - Solid Fluidized Bed

In the present work an attempt has been made to study the effect of the twisted tapes as bed internals, on the performance of the gas-solid fluidized beds. Experimental investigation has been carried out in cylindrical column with and without twisted tapes. Twelve numbers of twisted tapes of three different widths with four values of the twist ratios for each width were studied at different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014