An in vitro comparison of tracheostomy tube cuffs

نویسندگان

  • Seamus Maguire
  • Frances Haury
  • Korinne Jew
چکیده

INTRODUCTION The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. METHODS Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. RESULTS The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. CONCLUSION In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheal size following tracheostomy with cuffed tracheostomy tubes: an experimental study.

In view of the severe damage caused by unyielding, low residual volume cuffs, various modifications to the cuff of an intratracheal tube have been introduced. The merits of two low-pressure cuffs were assessed in an experimental study in dogs; both cuffs produced little visible damage to the tracheal wall in dogs intubated continuously over a two-week period. A modified technique of producing t...

متن کامل

Tracheostomy tubes and related appliances.

Tracheostomy tubes are used to administer positive-pressure ventilation, to provide a patent airway, to provide protection from aspiration, and to provide access to the lower respiratory tract for airway clearance. They are available in a variety of sizes and styles, from several manufacturers. The dimensions of tracheostomy tubes are given by their inner diameter, outer diameter, length, and c...

متن کامل

Evaluation of a teaching tool to increase the accuracy of pilot balloon palpation for measuring tracheostomy tube cuff pressure.

OBJECTIVES/HYPOTHESIS The purpose of this study was to evaluate the efficacy of a novel teaching tool to improve health care providers' ability to inflate tracheostomy tube cuffs to the appropriate pressure. STUDY DESIGN Single-blinded, randomized, controlled trial. METHODS Subjects were randomized to a control and study group. The control group viewed a video about inflating tracheostomy t...

متن کامل

Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics.

This study compared intracuff pressure (ICP) during mechanical ventilation in a variety of currently used endotracheal (ET) and tracheostomy (trach) tube cuffs and related cuff physical characteristics. Tracheostomy tube physical characteristics were also measured. Variation was observed to exist between "just-seal" inspiratory and end-expiratory intracuff pressure during mechanical ventilation...

متن کامل

Trach tubes designed to maximize safety may increase risk to ventilated patients

Dual-cannulae tracheostomy tubes with low-pressure cuffs, such as the Shiley LPC, are widely regarded as inherently safer than single lumen tubes with low-volume cuffs. For the patient who undergoes tracheostomy for failure to wean from mechanical ventilation, however, the insertion of a tube that occupies a large amount of space within the trachea can delay subsequent efforts to liberate him f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015