A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
نویسندگان
چکیده
Active-fixation pacing leads allow the use of selective pacing sites. We evaluated their long-term performance versus passive-fixation leads in 199 newly implanted patients (n = 100 active and n = 99 passive). Postoperative pacing thresholds in the active group were higher than in the passive group (0.85 ± 0.31 V vs. 0.53 ± 0.21 V at baseline, P < 0.001). The active thresholds fell to 0.72 ± 0.23 V at 5 years with a significant drop at one month (0.68 ± 0.53 V, P = 0.003). The passive thresholds slightly increased to 0.72 ± 0.31 V at five years. Differences between groups were significant until three years (all P < 0.05). Active impedances were generally lower than passive impedances (600.44 ± 94.31Ω vs. 683.14 ± 110.98Ω at baseline), and both showed significant reductions at one month to 537.96 ± 147.43Ω in the active group, and after three months to 643.85 ± 82.40Ω in the passive group (both P < 0.01 vs. baseline). Impedance differences between groups were significant until four years (all P < 0.05). Adverse events included thresholds over 1 V, 5 of 6 active and 2 of 5 passive leads returned to below 1 V. One active left ventricular lead dislodged. One passive left subclavian lead insulation fracture occurred. Thus Active fixation pacing leads are stable in a five-year long-term follow up. There was no difference between active and passive leads in terms of electrical performance.
منابع مشابه
Comparison of mid-term clinical experience with steroid-eluting active and passive fixation ventricular electrodes in children.
Although active fixation ventricular leads seem to have advantages over passive fixation leads, this study compares the follow-up results of active and passive fixation leads in children. We evaluated the implantation and follow-up data of 41 children with active (Accufix II DEC, group 1) (n = 20) or passive (Membrane E, group 2) (n = 21) fixation, steroid-eluting ventricular leads. All but one...
متن کاملSafety, Handling and Electrical Performances of Bradycardia Leads in Acute Conditions: Results from the FINE Registry
Background: Beflex is an active fixation atrial and ventricular lead with a retractable screw; X-Fine is a passive fixation ventricular lead. These two bradycardia lead models were evaluated in the FINE study, an observational prospective trial conducted in France and Spain. Methods: Patients enlisted for pacemaker or defibrillator implants were enrolled. The primary objective was to assess acu...
متن کاملLong-term performance of the Medtronic Sprint Fidelis lead: a matter of lead type?
AIMS In 2007, the Medtronic™ Sprint Fidelis(®) lead was withdrawn from the market due to elevated failure rates. Since then, several studies were published with failure rates between 1.3 and 3.75%/year. However, they included a very high percentage of active fixation leads. Data in a population with passive leads are missing. METHODS AND RESULTS All 166 patients who received a Fidelis lead be...
متن کاملRight Ventricular Pacing and Sensing Function in High Posterior Septal and Apical Lead Placement in Cardiac Resynchronization Therapy
BACKGROUND The conventional right ventricular (RV) lead position in cardiac resynchronization therapy pacemakers (CRT-P) is the RV apex (RV-A). Little is known about electrophysiological stability and associated complications of pacing leads in RV high posterior septal (RV-HS) position in CRT-P. METHODS Two hundred and thirty-five consecutive CRT-P patients were included from 1999-2010. Pacin...
متن کاملLong-term reliability of sweet-tip type screw-in leads
BACKGROUND Active fixation leads have provided stable atrial and ventricular pacing; however, long-term follow-up data have not been satisfactory. The purpose of this study was to investigate the long-term reliability of active fixation leads and their electrical characteristic stability. METHODS A total of 1196 pacing leads were implanted in 830 patients consecutively between 2002 and 2013. ...