Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow.

نویسندگان

  • Rikard Ambrus
  • Rune B Strandby
  • Lars Bo Svendsen
  • Michael P Achiam
  • John F Steffensen
  • Morten Bo Søndergaard Svendsen
چکیده

BACKGROUND/AIMS Microvascular blood flow is essential for healing and predicts surgical outcome. The aim of the current study was to investigate the relation between fluxes measured with the laser speckle contrast imaging (LSCI) technique and changes in absolute blood flow. In addition, we studied the reproducibility of the LSCI technique when assessing the intra-abdominal microcirculation of the pig. METHODS During trial 1, a fish gill arch was mechanically perfused with heparinized fish blood under controlled stepwise-altered flow rates alongside mechanically induced movement artefacts. The microcirculation of the fish gill was simultaneously assessed with the LSCI technique. In trial 2, microcirculation was measured in the stomach, liver, and small intestine of 10 pigs by two observers. RESULTS A linear correlation was observed between flux and volumetric flow. During conditions of no volumetric flow, the high recording speed with the LSCI technique registered the movement artefacts as flow signals. The LSCI measurements showed good correlation and agreement between the two observers when assessing microcirculation in the stomach, liver, and small intestine (r2 = 0.857, 0.956, and 0.946; coefficients of variation = 6.0, 3.2, and 6.4%, respectively). CONCLUSION Due to the non-contact and real-time assessment over large areas, LSCI is a promising technique for the intraoperative assessment of intra-abdominal microcirculation. A linear correlation between flux and volumetric flow was found, in accordance with previous experimental studies. However, movement artefacts affect flux measurements, and the choice of the sampling speed must be made with care, depending on the given setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of water flow velocity with fluorescent and speckle imaging technique

The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...

متن کامل

A novel effective method for the assessment of microvascular function in male patients with coronary artery disease: a pilot study using laser speckle contrast imaging

Evaluation of microvascular endothelial function is essential for investigating the pathophysiology and treatment of cardiovascular and metabolic diseases. Although laser speckle contrast imaging technology is well accepted as a noninvasive methodology for assessing microvascular endothelial function, it has never been used to compare male patients with coronary artery disease with male age-mat...

متن کامل

Laser speckle imaging for monitoring blood flow dynamics in the in vivo rodent dorsal skin fold model.

The rodent dorsal skin fold model is used routinely as a means to study changes in microvasculature flow and architecture (Barton et al., 2001; Friesenecker et al., 1994; Gourgouliatos et al., 1990; Mordon et al., 1997; Tsuzuki et al., 2000; Vargas et al., 2001; Wettstein et al., 2003). A method for high spatial and temporal resolution imaging of blood flow dynamics is required to provide objec...

متن کامل

Linear response range characterization and in vivo application of laser speckle imaging of blood flow dynamics.

Noninvasive blood flow imaging can provide critical information on the state of biological tissue and the efficacy of approaches to treat disease. With laser speckle imaging (LSI), relative changes in blood flow are typically reported, with the assumption that the measured values are on a linear scale. A linear relationship between the measured and actual flow rate values has been suggested. Th...

متن کامل

Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imaging.

Laser speckle contrast imaging is becoming an established method for full-field imaging of cerebral blood flow dynamics in animal models. The sensitivity and noise in the measurement of blood flow changes depend on the camera exposure time. The relation among sensitivity, noise, and camera exposure time was investigated experimentally by imaging the speckle contrast changes in the brain after e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European surgical research. Europaische chirurgische Forschung. Recherches chirurgicales europeennes

دوره 56 3-4  شماره 

صفحات  -

تاریخ انتشار 2016