A method to improve dose gradient for robotic radiosurgery
نویسندگان
چکیده
For targets with substantial volume, collimators of relatively large size are usually selected to minimize the treatment time in robotic radiosurgery. Their large penumbrae may adversely affect the dose gradient around the target. In this study, we implement and evaluate an inner-shell planning method to increase the dose gradient and reduce dose to normal tissues. Ten patients previously treated with CyberKnife M6 system were randomly selected with the only criterion being that PTV be larger than 2 cm(3). A new plan was generated for each patient in which the PTV was split into two regions: a 5 mm inner shell and a core, and a 7.5 mm Iris collimator was exclusively applied to the shell, with other appropriate collimators applied to the core depending on its size. The optimization objective, functions, and constraints were the same as in the corresponding clinical plan. The results were analyzed for V12 Gy, V9 Gy, V5 Gy, and gradient index (GI). Volume reduction was found for the inner-shell method at all studied dose levels as compared to the clinical plans. The absolute dose-volume reduction ranged from 0.05 cm(3) to 18.5 cm(3) with a mean of 5.6 cm(3) for 12 Gy, from 0.2 cm(3) to 38.1 cm(3) with a mean of 9.8 cm(3) for 9 Gy, and from 1.5 cm(3) to 115.7 cm(3) with a mean of 24.8 cm(3) for 5 Gy, respectively. The GI reduction ranged from 3.2% to 23.6%, with a mean of 12.6%. Paired t-test for GI has a p-value of 0.0014. The range for treatment time increase is from -3 min to 20 min, with a mean of 7.0 min. We conclude that irradiating the PTV periphery exclusively with the 7.5 mm Iris collimator, rather than applying mixed collimators to the whole PTV, can substantially improve the dose gradient, while maintaining good coverage, conformity, and reasonable treatment time.
منابع مشابه
A Dose–Volume Response Model for Brain Metastases Treated With Frameless Single-Fraction Robotic Radiosurgery: Seeking to Better Predict Response to Treatment
Purpose/Objective(s): To establish a dose-volume response relationship for brain metastases treated with single-fraction robotic stereotactic radiosurgery and identify predictors of local control. MATERIALS/METHODS We reviewed a prospective institutional database of all patients treated for intact brain metastases with stereotactic radiosurgery alone using the CyberKnife robotic radiosurgery ...
متن کاملA spherical dose model for radiosurgery plan optimization.
Conventional 3D dose calculations for stereotactic radiosurgery involve integration of individual static beams comprising a set of arcs. For iterative optimization of multiple isocentre treatment, which requires repetitive dose calculations at a large number of sample points, the conventional method is too slow. To overcome this problem spherically symmetric dose distributions are assumed. The ...
متن کاملCyberknife Radiosurgery – A New Treatment Method for Image-guided, Robotic, High-precision Radiosurgery
Cyberknife Radiosurgery – Overview Cyberknife technology is based on radiosurgical principles that have been in clinical practice for 30 years. Radiosurgery is the precise application of a high (tumour-destructing) dose of radiation in a precisely defined target volume, while protecting the surrounding healthy tissue. During radiosurgery, many radiation beams from different directions intersect...
متن کاملRobotic radiosurgery system patient‐specific QA for extracranial treatments using the planar ion chamber array and the cylindrical diode array
Robotic radiosurgery system has been increasingly employed for extracranial treatments. This work is aimed to study the feasibility of a cylindrical diode array and a planar ion chamber array for patient-specific QA with this robotic radiosurgery system and compare their performance. Fiducial markers were implanted in both systems to enable image-based setup. An in-house program was developed t...
متن کاملSU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.
PURPOSE The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. METHODS ...