Pacing and Sensing of Human Heart for over 31 Years with the Same Apparatus (Generator and Lead)
نویسندگان
چکیده
Several patients receive a permanent pacemaker in a relatively young age, with multiple subsequent reoperations for pacemaker replacement. Pulse generator replacement is an invasive procedure, associated with the risk of various complications, mainly infection and skin erosion. A case of an extremely long-lasting pacemaker with a totally uneventful longevity period over 31 years is presented. The explanation for this quite rare pacemaker longevity (possibly unique) is analyzed and discussed.
منابع مشابه
Pacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملIncidence of lead system malfunction detected during implantable defibrillator generator replacement.
Implantable cardioverter-defibrillator (ICD) generator replacement due to a depleted battery is a frequently performed procedure. The frequency with which sensing and defibrillation system failures are identified during device replacement procedures has not been previously described. Therefore, the purpose of this study was to prospectively determine the frequency of lead system malfunction det...
متن کاملPermanent epicardial pacing in pediatric patients: seventeen years of experience and 1200 outpatient visits.
BACKGROUND The purpose of this study was to evaluate the long-term outcome of all pediatric epicardial pacing leads. METHODS AND RESULTS All epicardial leads and 1239 outpatient visits between January 1, 1983, and June 30, 2000, were retrospectively reviewed. Pacing and sensing thresholds were reviewed at implant, at 1 month, and at subsequent 6-month intervals. Lead failure was defined as th...
متن کاملInappropriate sensing events revealing electrocautery-induced implantable cardioverter–defibrillator lead failure
Electromagnetic interference (EMI) associated with current implantable cardioverter–defibrillator (ICD) generators and leads are less prone to long-term failure. Thus, it has been suggested that routine post-ICD replacement interrogation of the device may not be necessary. We present the case of a patient who underwent ICD replacement during which therapies were inadvertently not turned off, wh...
متن کاملIntermittent loss of capture in a His bundle pacemaker: What is the cause?
Case report A 34-year-old man with a history of congenital complete heart block who underwent dual-chamber pacemaker implant at age 6 and multiple generator changes was referred for device replacement and lead extraction owing to malfunctioning atrial and ventricular leads. He underwent lead extraction of a dual-chamber pacing system with subsequent reimplantation of a Medtronic Viva CRT pacema...