Monitoring: Arterial and Pulmonary Artery Catheters

نویسنده

  • SHARON E. MORAN
چکیده

55. Treister N, Wagner K, Jansen PR. Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease. Am J Hypertens. 2005;18(Pt 2):44S–50S. 56. Barcarse E, Kazanegra R, Chen A, et al. Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department. Cong Heart Fail. 2004;10:171–176. 57. Packer M, Abraham WT, Mehra MR, et al. Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure. J Am Coll Cardiol. 2006;47:2245– 2252. 58. Sanford T, Treister N, Peters C. Use of noninvasive hemodynamics in hypertension management. Am J Hypertens. 2005;8(Pt 2):87S–91S. 59. Ramirez MF, Tibayan RT, Marinas CE, et al. Prognostic value of hemodynamic findings from impedance cardiography in hypertensive stroke. Am J Hypertens. 2005;18(Pt 2):65S–72S. 60. Kaukinen S, Koobi T, Bi Y, et al. Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography. J Cardiothor Vasc Anesth. 2003;17:199–203. 61. Kauppinen PK, Koobi T, Hyttinen J, et al. Segmental composition of wholebody impedance cardiogram estimated by computer simulations and clinical experiments. Clin Physiol. 2000;20:106–113. 62. Koobi T, Kaukinen S, Turjanmaa VM, et al. Whole-body impedance cardiography in the measurement of cardiac output. Crit Care Med. 1997;25:779– 785. 63. Linton RA, Band DM, Haire KM. A new method for measuring cardiac output using lithium dilution. Br J Anaesth. 1993;71:262–266. 64. Nichols WW, O’Rourke MF. MacDonald’s Blood Flow in Arteries. 5th ed. London: Hodder Arnold Publication; 2005. 65. Linton NWP, Linton RAF. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Br J Anaesth. 2001;86:486–494. 66. Capek JM, Roy RJ. IEEE Trans BME. 1988:653–661. 67. Jaffe MB:. Partial CO2 rebreathing cardiac output: operating principles of the NICO system. J Clin Monit. 1999;15:387–401. 68. Tordi N, Mourot L, Matusheski B, et al. Measurements of cardiac output during constant exercises: comparison of two non-invasive techniques. Int J Sports Med. 2004;25:145–149. 69. Beilman GJ, Groehler KE, Lazaron V, et al. Near infrared spectroscopy measurement of regional tissue oxyhemoglobin saturation during hemorrhagic shock. Shock. 1999;12:196–200. 70. Cohn SM, Crookes BA, Proctor KG. Near-infrared spectroscopy in resuscitation. J Trauma. 2003;54(5):S199–S202. 71. Myers DE, Anderson LD, Seifert RP, et al. Noninvasive method for measuring local hemoglobin oxygen saturation in tissue using wide gap second derivative near-infrared spectroscopy. J Biomed Optics. 2005;10(3):1– 18.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of thoracic epidural blockade on hypoxia-induced pulmonary arterial hypertension in rats

Objective(s): The present study was aimed to investigate the influence of thoracic epidural blockade on hypoxia-induced pulmonary hypertension in rats. Materials and Methods: Forty eight Wistar rats were randomly divided into 4 equal groups, named normoxia hypoxia hypoxia/ ropivacaine and hypoxia/saline. Animals were placed in a hypoxia chamber and instrumented with epidural catheters at the t...

متن کامل

0866. Repercussion in hemodynamic values and extravascular lung water of alveolar recruitment maneuvers, in an experimental model of ARDS

C group Control group: without RA, using PEEP values bellow LIP (lower inflection point). The hemodynamic study (Heart rate, mean BP, PCP, PAP, CI), EVLW, and lactic acid, was made at basal time and at 15, 60, 180 and 360 minutes, after the provocation of ARDS. The catheters used for hemodynamic monitoring consisted in: venous catheters, arterial catheters and pulmonary artery catheter for dete...

متن کامل

Mechanical Aspects of Cardiac Performance

Monitoring of hemodynamic and mechanical parameters of the heart are reviewed. Clinical methodologies are discussed along with tools used in a research setting. Specifically, these include: arterial blood pressure, central venous pressure, pulmonary artery pressure, mixed venous oxygen saturation, cardiac output, pressure–volume loops, flow monitoring, and Frank–Starling curves. These parameter...

متن کامل

Complications of invasive monitoring.

Invasive monitoring in anesthesiology is relatively safe. Arterial catheterization in particular has an extremely low rate of serious complications. Radial, brachial, and femoral artery catheterization sites appear to have similar and low complication rates. CVP and PA catheters are more dangerous and entail potentially fatal complications. The most troublesome complication with CVP catheters i...

متن کامل

An unusual manifestation of pulmonary artery perforation during pulmonary artery catheter insertion.

P ULMONARY ARTERY balloon-tipped catheters are commonly inserted in critically ill patients as a source of physiologic data useful in planning management and evaluating the efficacy of treatment. Pulmonary artery perforation with resultant massive hemoptysis is a known complication of the use of these catheters, with an occurrence of 0.064% in one large series.’ The perforations with hemorrhage...

متن کامل

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010