Poorly processed reusable surface disinfection tissue dispensers may be a source of infection

نویسندگان

  • Günter Kampf
  • Stina Degenhardt
  • Sibylle Lackner
  • Katrin Jesse
  • Heike von Baum
  • Christiane Ostermeyer
چکیده

BACKGROUND Reusable surface disinfectant tissue dispensers are used in hospitals in many countries because they allow immediate access to pre-soaked tissues for targeted surface decontamination. On the other hand disinfectant solutions with some active ingredients may get contaminated and cause outbreaks. We determined the frequency of contaminated surface disinfectant solutions in reusable dispensers and the ability of isolates to multiply in different formulations. METHODS Reusable tissue dispensers with different surface disinfectants were randomly collected from healthcare facilities. Solutions were investigated for bacterial contamination. The efficacy of two surface disinfectants was determined in suspension tests against two isolated species directly from a contaminated solution or after 5 passages without selection pressure in triplicate. Freshly prepared use solutions were contaminated to determine survival of isolates. RESULTS 66 dispensers containing disinfectant solutions with surface-active ingredients were collected in 15 healthcare facilities. 28 dispensers from nine healthcare facilities were contaminated with approximately 107 cells per mL of Achromobacter species 3 (9 hospitals), Achromobacter xylosoxidans or Serratia marcescens (1 hospital each). In none of the hospitals dispenser processing had been adequately performed. Isolates regained susceptibility to the disinfectants after five passages without selection pressure but were still able to multiply in different formulations from different manufacturers at room temperature within 7 days. CONCLUSIONS Neglecting adequate processing of surface disinfectant dispensers has contributed to frequent and heavy contamination of use-solutions based on surface active ingredients. Tissue dispenser processing should be taken seriously in clinical practice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective reprocessing of reusable dispensers for surface disinfection tissues – the devil is in the details

BACKGROUND It has recently been reported that reusable dispensers for surface disinfection tissues may be contaminated, especially with adapted Achromobacter species 3, when products based on surface-active ingredients are used. Fresh solution may quickly become recontaminated if dispensers are not processed adequately. METHODS We evaluated the abilities of six manual and three automatic proc...

متن کامل

Outbreak of Serratia marcescens in a neonatal intensive care unit: contaminated unmedicated liquid soap and risk factors.

This study describes an outbreak of Serratia marcescens and its investigation and control in a neonatal intensive care unit (NICU). During a three-month period, five infants were colonised or infected by a single strain of S. marcescens. A case-control study, culture surveys and pulse-field gel electrophoresis analysis implicated a bottle soap dispenser as a reservoir of S. marcescens (P=0.032)...

متن کامل

Thermal Plasma-processed Natural Hydroxyapatite-MnO2 Nanoparticles as a Reusable and Green Heterogeneous Catalyst for Aerobic Oxidation of Benzylic Alkyl Arenes and Alcohols

In the present work, we have reported the in situ oxidation of manganese (II) acetate to MnO2 nanoparticles through the thermal plasma carbonized natural hydroxyapatite (MnO2/TP-NHAp) as a neoteric sustainable method. Interestingly, the thermal plasma-processed surface of the NHAp shows a great ability for oxidation of the manganese (II) without need of any external oxidizing agents. The cataly...

متن کامل

Pseudobacteremia outbreak of biofilm-forming Achromobacter xylosoxidans – environmental transmission

BACKGROUND Achromobacter xylosoxidans (AX) is known for intrinsic resistance to disinfectants. Our laboratory routine surveillance system detected an unexpected rise in AX bloodstream infections in a 2200-bed hospital. An epidemiological investigation was conducted to find the source and disrupt further transmission. METHODS Outbreak cases were defined as patients with at least one positive b...

متن کامل

Recommendations and requirements for soap and hand rub dispensers in healthcare facilities

Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014