Specific absorption rate reduction using nonlinear gradient fields.
نویسندگان
چکیده
The specific absorption rate is used as one of the main safety parameters in magnetic resonance imaging. The performance of imaging sequences is frequently hampered by the limitations imposed on the specific absorption rate that increase in severity at higher field strengths. The most well-known approach to reducing the specific absorption rate is presumably the variable rate selective excitation technique, which modifies the gradient waveforms in time. In this article, an alternative approach is introduced that uses gradient fields with nonlinear variations in space to reduce the specific absorption rate. The effect of such gradient fields on the relationship between the desired excitation profile and the corresponding radiofrequency pulse is shown. The feasibility of the method is demonstrated using three examples of radiofrequency pulse design. Finally, the proposed method is compared with and combined with the variable rate selective excitation technique.
منابع مشابه
Novel Techniques regarding Specific Absorption Rate and Field of View Reduction in Magnetic Resonance Imaging
NOVEL TECHNIQUES REGARDING SPECIFIC ABSORPTION RATE AND FIELD OF VIEW REDUCTION IN MAGNETIC RESONANCE IMAGING Emre Kopanoglu Ph.D. in Electrical and Electronics Engineering Supervisors: Prof. Dr. Ergin Atalar Assoc. Prof. Dr. Vakur B. Ertürk September, 2012 In this dissertation, novel strategies regarding the reduction of the specific absorption rate (SAR) and the reduction of the total scan ti...
متن کاملGradient Estimates for a Degenerate Parabolic Equation with Gradient Absorption and Applications
Qualitative properties of non-negative solutions to a quasilinear degenerate parabolic equation with an absorption term depending solely on the gradient are shown, providing information on the competition between the nonlinear diffusion and the nonlinear absorption. In particular, the limit as t → ∞ of the L1-norm of integrable solutions is identified, together with the rate of expansion of the...
متن کاملSpecific absorption rates and induced current densities for an anatomy-based model of the human for exposure to time-varying magnetic fields of MRI.
A 6-mm resolution, 30-tissue anatomy-based model of the human body is used to calculate specific absorption rate (SAR) and the induced current density distributions for radiofrequency and switched gradient magnetic fields used for MRI, respectively. For SAR distributions, the finite-difference time-domain (FDTD) method is used including modeling of 16-conductor birdcage coils and outer shields ...
متن کاملA new algorithm of nonlinear conjugate gradient method with strong convergence*
The nonlinear conjugate gradient method is a very useful technique for solving large scale minimization problems and has wide applications in many fields. In this paper, we present a new algorithm of nonlinear conjugate gradient method with strong convergence for unconstrained minimization problems. The new algorithm can generate an adequate trust region radius automatically at each iteration a...
متن کاملMultiparametric cardiovascular magnetic resonance assessment of pacemaker-induced alterations in ventricular activation and function.
A 73-year-old woman with presyncope and frequent episodes of symptomatic 2:1 atrioventricular block underwent implantation of a dual-chamber MRI-conditional pacing system (Advisa MRI SureScan pacing system, Medtronic, Minneapolis, MN) to facilitate cardiovascular magnetic resonance (CMR) assessment of apparent isolated right ventricular (RV) hypertrophy seen on transthoracic echocardiography (F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 70 2 شماره
صفحات -
تاریخ انتشار 2013