Comparison of two semiautomated methods for evaluating endothelial cells of eye bank corneas.

نویسندگان

  • Nilanjana Deb-Joardar
  • Gilles Thuret
  • Min Zhao
  • Sophie Acquart
  • Michel Péoc'h
  • Olivier Garraud
  • Philippe Gain
چکیده

PURPOSE To compare two semiautomated methods of evaluating endothelial cells of eye bank corneas. METHODS Using a commercially available semiautomatic endothelial analyzer, seven observers determined the endothelial cell density (ECD), coefficient of variation (CV) of cell area, and the percentage of hexagonal cells (hexagonality) of the light microscopic images of the endothelium of 30 organ-cultured corneas. The image quality was graded as good, average, and poor. Border (contour detection and manual retouch) and center (indicating cell centers) methods for identifying endothelial cells were compared. The interobserver variability in ECD determination (indicating reproducibility) and morphometry was statistically analyzed by using the two methods. The importance of accurate pointing of cell centers was assessed by counting on 10 standard photolithographic mosaics and noting the time taken. RESULTS There was no significant difference in the interobserver variability or between ECDs obtained by the border and center methods. Decrease in image quality had a similar influence on both methods. Although measurement of hexagonality was acceptable by both methods, the CV was reliable only with the border method, with a significant underestimation by the center METHOD However, an accurate indication of cell center slightly improved the CV estimation. CONCLUSIONS Although both the border and center methods of semiautomatic evaluation of eye bank corneas measure similar ECD with a similar reproducibility, only the border method gives a reliable morphometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 3-decade Activity of the Central Eye Bank of Iran

Purpose: To report a 3-decade eye bank data and activity of the Central Eye Bank of Iran (CEBI). Methods: All the eye bank records in terms of procured eyes, utilized tissues, corneal transplants per capita, and indications for keratoplasty over the last 3 decades were analyzed. Results: During the last 27 years, 115 743 whole eyes were donated, among which 114 169 eyes were donated between 199...

متن کامل

Endothelial Cell Viability of Donor Corneas Preserved in Eusol-C Corneal Storage Medium.

OBJECTIVES To evaluate the efficacy of Eusol-C as a corneal storage medium on the survival of donor endothelium. MATERIALS AND METHODS Twenty-seven corneas not suitable for transplant were included in this study. All donor corneas were stored in Eusol-C at 4°C. Daily donor corneal endothelial cell counting was performed with an eye bank specular microscope. All corneas were discarded after th...

متن کامل

ATPase pump site density in human dysfunctional corneal endothelium.

Proper corneal hydration is maintained by a Na, K-ATPase pump located in the lateral membranes of the endothelial cells. In dysfunctional corneas this pumping action appears to break down as the corneas become edematous. In order to provide quantitative and qualitative data on the Na, K-ATPase pump site density on dysfunctional and functional human corneal endothelial cells, the present study h...

متن کامل

A new system for the automatic estimation of endothelial cell density in donor corneas.

AIMS The problem of automatic estimation of endothelial cell density from microscopy images in donor corneas was addressed. METHODS The spatial frequencies contained in digital endothelium images are extracted with a two dimension discrete Fourier transform (DFT) technique. A circular band in the DFT of the images is shown to contain the frequency information related to the cell density. An a...

متن کامل

Organ culture preservation for corneal tissue. Technical and quality aspects.

INTRODUCTION The technical and quality aspects of organ culture as a storage method for human donor corneas are described. MATERIALS AND METHODS Data electronically stored since 1989 of > 41,000 corneas, processed in the Cornea Bank Amsterdam, are analysed. The technical information of eye banks collected in the Directory of the European Eye Bank Association (EEBA) is used as comparison. Euro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2007