Toward Nanometer-Scale Resolution in Fluorescence Microscopy Using Spectral Self-Interference

نویسندگان

  • Anna K. Swan
  • Lev A. Moiseev
  • C. R. Cantor
  • Brynmor Davis
  • S. B. Ippolito
  • William Clem Karl
  • Bennett B. Goldberg
  • Selim Ünlü
چکیده

We introduce a new fluorescence microscopy technique that maps the axial position of a fluorophore with subnanometer precision. The interference of the emission of fluorophores in proximity to a reflecting surface results in fringes in the fluorescence spectrum that provide a unique signature of the axial position of the fluorophore. The nanometer sensitivity is demonstrated by measuring the height of a fluorescein monolayer covering a 12-nm step etched in silicon dioxide. In addition, the separation between fluorophores attached to the top or the bottom layer in a lipid bilayer film is determined. We further discuss extension of this microscopy technique to provide resolution of multiple layers spaced as closely as 10 nm for sparse systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence Imaging with Nanometer Precision Using Spectral Self-interference Microscopy

Spectral Self-Interference Fluorescence Microscopy (SSFM) has been shown to allow nanometer-scale localization of fluorescent layers placed above a reflecting substrate. A MonteCarlo analysis is used to show how this high localization accuracy can still be expected at the low signal levels associated with single-molecule studies. Discrimination of fluorophores separated by a few tens of nanomet...

متن کامل

Three-dimensional Localization of Nano-emitters with Nanometer-level Precision

We show nanometer-level localization accuracy of a single quantum-dot in three dimensions by self-interference and diffraction-pattern analysis. We believe that this approach has the capacity to push optical microscopy to the molecular level. ©2009 Optical Society of America OCIS codes: (180.2520) Fluorescence microscopy; (260.3160) Interference; (100.6640) Superresolution The use of fluorescen...

متن کامل

Analysis of Multi - Channel Microscopy : Spectral Self - Interference , Multi - Detector Confocal and 4 Pi Systems

Fluorescence microscopy is an important and ubiquitous tool in biological imaging due to the high specificity with which fluorescent molecules can be attached to an organism and the subsequent nondestructive in-vivo imaging allowed. Focused-light microscopies allow three-dimensional fluorescence imaging but their resolution is restricted by diffraction. This effect is particularly limiting in t...

متن کامل

4Pi spectral self-interference microscopy.

Spectral self-interference microscopy (SSM) relies on the balanced collection of light traveling two different paths from the sample to the detector, one direct and the other indirect from a reflecting substrate. The resulting spectral interference effects allow nanometer-scale axial localization of isolated emitters. To produce spectral fringes the difference between the two optical paths must...

متن کامل

Biological applications of spectral self-interference

An original technique, Spectral Self-Interference Fluorescence Microscopy (SSFM), can determine the location of fluorescent markers above a reflecting surface with sub-nanometer precision. SSFM was used to resolve the position of a fluorescent marker bound to either the top or the bottom leaflet of a lipid bilayer – the difference in distance is only 4 nm. SSFM is a valuable tool in studying th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001