The region ion sensitive field effect transistor, a novel bioelectronic nanosensor.
نویسندگان
چکیده
A novel type of bioelectronic region ion sensitive field effect transistor (RISFET) nanosensor was constructed and demonstrated on two different sensor chips that could measure glucose with good linearity in the range of 0-0.6mM and 0-0.3mM with a limit of detection of 0.1 and 0.04 mM, respectively. The sensor is based on the principle of focusing charged reaction products with an electrical field in a region between the sensing electrodes. For glucose measurements, negatively charged gluconate ions were gathered between the sensing electrodes. The signal current response was measured using a low-noise pico ammeter (pA). Two different sizes of the RISFET sensor chips were constructed using conventional electron beam lithography. The measurements are done in partial volumes mainly restricted by the working distance between the sensing electrodes (790 and 2500 nm, respectively) and the influence of electrical fields that are concentrating the ions. The sensitivity was 28 pA/mM (2500 nm) and 830 pA/mM (790 nm), respectively. That is an increase in field strength by five times between the sensing electrodes increased the sensitivity by 30 times. The volumes expressed in this way are in low or sub femtoliter range. Preliminary studies revealed that with suitable modification and control of parameters such as the electric control signals and the chip electrode dimensions this sensor could also be used as a nanobiosensor by applying single enzyme molecule trapping. Hypotheses are given for impedance factors of the RISFET conducting channel.
منابع مشابه
Extended-Gate Field-Effect Transistor based Sensor for Detection of Hyoscine N-Butyl Bromide in its Pharmaceutical Formulation
A novel recognition method for selective determination of the hyoscine N-Butyl bromide (HBB), an antispasmodic agent for smooth muscles, was devised using extended gate field-effect transistor (EG-FET) as transducing unit. For this purpose a PVC membrane, containing hyoscine n-butyl-tetraphenyl borate ion-pair as recognition component, was coated on Ag/AgCl wire, which was connected to the exte...
متن کاملA novel lightly doped drain and source Carbon nanotube field effect transistor (CNTFET) with negative differential resistance
In this paper, we propose and evaluate a novel design of a lightly doped drain and source carbon nanotube field effect transistor (LDDS-CNTFET) with a negative differential resistance (NDR) characteristic, called negative differential resistance LDDS-CNTFET (NDR-LDDS-CNTFET). The device was simulated by using a non equilibrium Green’s function method. To achieve this phenomenon, we have created...
متن کاملA novel lightly doped drain and source Carbon nanotube field effect transistor (CNTFET) with negative differential resistance
In this paper, we propose and evaluate a novel design of a lightly doped drain and source carbon nanotube field effect transistor (LDDS-CNTFET) with a negative differential resistance (NDR) characteristic, called negative differential resistance LDDS-CNTFET (NDR-LDDS-CNTFET). The device was simulated by using a non equilibrium Green’s function method. To achieve this phenomenon, we have created...
متن کاملField Effect Transistor Nanosensor for Breast Cancer Diagnostics
Silicon nanochannel field effect transistor (FET) biosensors are one of the most promising technologies in the development of highly sensitive and label-free analyte detection for cancer diagnostics. With their exceptional electrical properties and small dimensions, silicon nanochannels are ideally suited for extraordinarily high sensitivity. In fact, the high surface-to-volume ratios of these ...
متن کاملSimulation study of the performance of a biologically sensitive field effect transistor
The transformation of biochemical information into a physical or chemical signal is the basic idea behind a biosensor. The efficient detection of charged biomolecules by biosensor with appropriate device has caught tremendous research interest in the present decade. The present work is related to the simulation study of the performance of a functionalized surface of a biologically sensitive fie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 22 12 شماره
صفحات -