Current Harmonics from Single-Phase Grid-Connected Inverters – Examination and Suppression

نویسنده

  • Yongheng Yang
چکیده

Environmental conditions and operational modes may significantly impact the distortion level of the injected current from single-phase grid-connected inverter systems, such as photovoltaic (PV) inverters, which may operate in cloudy days with a maximum power point tracking, in a non-unity power factor, or in the low voltage ride through mode with reactive current injection. In this paper, the mechanism of the harmonic current injection from grid-connected single-phase inverter systems is thus explored, and the analysis is conducted on single-phase PV systems. In particular, the analysis is focused on the impacts of the power factor and the feed-in grid current level on the quality of the feed-in grid current from single-phase inverters. As a consequence, an internal model principle based high performance current control solution is tailor-made and developed for single-phase grid-connected systems to produce high quality currents in different operation conditions, where a design procedure is also provided. The developed current controller in this paper can achieve a minimum steady-state error while maintaining a relatively fast transient response, and also being feasible in other single-phase applications as a promising harmonic mitigation solution. Experiments on single-phase gridconnected systems have verified the correctness of the relevant analysis and also the effectiveness of the tailor-made control solution in terms of good harmonic mitigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT

The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Lo...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Design and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller

In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...

متن کامل

The Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter

Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...

متن کامل

Control of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017