Comparison of methods for acceptance and constancy testing in dental cone-beam computed tomography.

نویسندگان

  • C Steiding
  • D Kolditz
  • W Kalender
چکیده

PURPOSE The aim of this work was to implement, validate, and compare two procedures for routine image quality (IQ) assurance in dental cone-beam computed tomography (CBCT): 1. the German standard DIN 6868 - 161 introduced in 2013 and 2. the established standard IEC 61,223 - 3-5 for clinical CT x-ray equipment referenced as "DIN" and "IEC" below. MATERIALS AND METHODS The approximated in-plane modulation transfer function (MTF), the contrast-to-noise indicator (CNI), and the uniformity indicator (UI*) were determined in accordance with DIN. Image noise, the uniformity index (UI), the contrast-to-noise ratio (CNR), and the 3 D MTF were measured according to IEC 61,223 - 3-5 using a previously proposed quality assurance (QA) framework. For this, a modular phantom was used. All experiments were performed on a clinical dental CBCT unit. The severity of image artefacts was measured at different z-positions. A dedicated computer program was implemented to allow for automated QA procedure. RESULTS The position and orientation of the phantoms were detected automatically in all of the measurements providing a reproducible placement of the evaluation regions and volumes. 50 % and 10 % in-plane MTF values of the approximated and the exact MTF calculation procedure were in agreement to within 5 %. With increasing axial distance from the isocentre, UI* and CNI dropped by 30 % and 19 %, respectively. Conventional IQ parameters showed higher sensitivity to image artefacts; i. e., UI and CNR were reduced by about 197 % and 37 %. CONCLUSION The implemented automated QA routines are compatible with both the DIN and the IEC approach and offer reliable and quantitative tracking of imaging performance in dental CBCT for clinical practice. However, there is no equivalence between the DIN and the IEC metrics. In addition, direct measurements of physical IQ parameters such as image contrast and noise, uniformity, and axial resolution are not supported by the new concept according to DIN. KEY POINTS The new DIN 6868 - 161 is not equivalent to the established IEC 61 223 - 3-5. Noise, uniformity, and contrast are well-suited to assess image artefacts. The implemented automated quality assurance program fits clinical routine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Comparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study

BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Foreign Body in Nasal Cavity: Panoramic and Cone-Beam Computed Tomography (CBCT) Findings

Introduction: Panoramic view as a routine dental radiograph has an important role in diagnosis of other facial abnormalities accompanied with dento- alveolar structures. In this case presentation, we discuss this subject and also the efficacy of cone-beam computed tomography in localization of foreign body in complex anatomy of nasal cavity.

متن کامل

Incidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population

BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...

متن کامل

Evaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran

BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 187 4  شماره 

صفحات  -

تاریخ انتشار 2015