Fast-FISH Detection and Semi-Automated Image Analysis of Numerical Chromosome Aberrations in Hematological Malignancies

نویسندگان

  • Arif Esa
  • Luba Trakhtenbrot
  • Michael Hausmann
  • Joachim Rauch
  • Frida Brok-Simoni
  • Gideon Rechavi
  • Isaac Ben-Bassat
  • Christoph Cremer
چکیده

A new fluorescence in situ hybridization (FISH) technique called Fast-FISH in combination with semi-automated image analysis was applied to detect numerical aberrations of chromosomes 8 and 12 in interphase nuclei of peripheral blood lymphocytes and bone marrow cells from patients with acute myelogenous leukemia (AML) and chronic lymphocytic leukemia (CLL). Commercially available alpha-satellite DNA probes specific for the centromere regions of chromosome 8 and chromosome 12, respectively, were used. After application of the Fast-FISH protocol, and microscopic images of the fluorescence-labelled cell nuclei were recorded by the true color CCD camera Kappa CF 15 MC and evaluated quantitatively by computer analysis on a PC. These results were compared to results obtained from the same type of specimens using the same analysis system but with a standard FISH protocol. In addition, automated spot counting after both FISH techniques was compared to visual spot counting after standard FISH. A total number of about 3,000 cell nuclei was evaluated. For quantitative brightness parameters, a good correlation between standard FISH labelling and Fast-FISH was found. Automated spot counting after Fast-FISH coincided within a few percent to automated and visual spot counting after standard FISH. The examples shown indicate the reliability and reproducibility of Fast-FISH and its potential for automatized interphase cell diagnostics of numerical chromosome aberrations. Since the Fast-FISH technique requires a hybridization time as low as 1/20 of established standard FISH techniques, omitting most of the time consuming working steps in the protocol, it may contribute considerably to clinical diagnostics. This may especially be interesting in cases where an accurate result is required within a few hours.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prompt cytomolecular identification of chromosome aberration in irradiated blood cells

Background: understanding the genomic alteration induced by ionizing radiation still remains to be a methodological challenge in genetic field. The energy released from this type of radiation can potentially causes structural and numerical alterations in lymphocytes, which in turn converts them into abnormal tumor cells. Chromosomal abnormalities associated with specific type of hematological m...

متن کامل

Semi-Automated FISH analysis of cells on slides Automated Post-Hybridization in a FISH protocol of leukaemia cells from blood with the Tecan GenePaint system

Fluorescence In situ hybridization (FISH) is a technique that can be used for the analysis of genomic aberrations in tumor cells. The resolution level of FISH is by far better than chromosome banding which is also widely used for the study of chromosome aberrations in cancer. In addition to the improved resolution FISH allows for the analysis of genomic aberrations not only on metaphase chromos...

متن کامل

Comparison of classical cytogenetics versus interphase FISH in diagnosis of mosaic form of Turner syndrome

 Abstract  Background: Mosaic form of turner syndrome that represented by two or more  cell lines in an affected individual, often has limitation for detection with classical  cytogenetic methods. The present study was carried out to compare the efficiency of  interphase Fluorescence In Situ Hybridisation (FISH) and cytogenetic techniques in  detection of mosaic form of turner syndrome.  Method...

متن کامل

Integration of microarray analysis into the clinical diagnosis of hematological malignancies: How much can we improve cytogenetic testing?

PURPOSE To evaluate the clinical utility, diagnostic yield and rationale of integrating microarray analysis in the clinical diagnosis of hematological malignancies in comparison with classical chromosome karyotyping/fluorescence in situ hybridization (FISH). METHODS G-banded chromosome analysis, FISH and microarray studies using customized CGH and CGH+SNP designs were performed on 27 samples ...

متن کامل

High Throughput FISH Analysis: A New, Sensitive Option For Evaluation of Hematological Malignancies

OBJECTIVE The aim of this study was to determine the efficiency of the high throughput FISH analysis (HTFA) method for detecting genetic alterations in hematological malignancies, which is a new bacterial artificial chromosome array-based approach. MATERIALS AND METHODS We performed a HTFA study of bone marrow aspiration and peripheral blood samples of 77 cases (n=19 myelodysplastic syndrome,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 1998