Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring.

نویسندگان

  • Dorothee Deiss
  • Jan Bolinder
  • Jean-Pierre Riveline
  • Tadej Battelino
  • Emanuele Bosi
  • Nadia Tubiana-Rufi
  • David Kerr
  • Moshe Phillip
چکیده

I ntensive self-management with frequent self-monitoring of blood glucose (SMBG) is important in type 1 diabetes to achieve good metabolic control (1–3). Nevertheless, many patients still experience episodes of unrecognized hypoand hyperglycemia (4). Novel technologies for continuous glucose monitoring (CGM) that provide information about glucose excursions are now available. Previous studies reported the benefits of retrospective evaluation of CGM data (5– 11), but few assessed effects on glycemic control (5,12–14), and only one showed improvements compared with SMBG (14). We evaluated the effect of a new real-time glucose monitor on glycemic control in patients with poorly controlled type 1 diabetes. The device, Guardian RT (Medtronic MiniMed, Northridge, CA), allows users to see glucose readings and set hypoand hyperglycemic alarms and provides trend information on changing glucose values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes

OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C >or=8...

متن کامل

Design and rationale of the IN CONTROL trial: the effects of real-time continuous glucose monitoring on glycemia and quality of life in patients with type 1 diabetes mellitus and impaired awareness of hypoglycemia

BACKGROUND Hypoglycemia is the main side effect of intensified insulin therapy in type 1 diabetes and recognized as a limitation in achieving glycemic targets. Patients with impaired awareness of hypoglycemia have a threefold to sixfold increased risk of severe hypoglycemia. Real-time continuous glucose monitoring may help patients with type 1 diabetes to achieve better glycemic control with le...

متن کامل

Combined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.

OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...

متن کامل

Assessment of Patient-Led or Physician-Driven Continuous Glucose Monitoring in Patients With Poorly Controlled Type 1 Diabetes Using Basal-Bolus Insulin Regimens

OBJECTIVE The benefits of real-time continuous glucose monitoring (CGM) have been demonstrated in patients with type 1 diabetes. Our aim was to compare the effect of two modes of use of CGM, patient led or physician driven, for 1 year in subjects with poorly controlled type 1 diabetes. RESEARCH DESIGN AND METHODS Patients with type 1 diabetes aged 8-60 years with HbA(1c) ≥ 8% were randomly as...

متن کامل

Effect of Acarbose on Glycemic Variability in Patients with Poorly Controlled Type 2 Diabetes Mellitus Receiving Stable Background Therapy: A Placebo-Controlled Trial.

STUDY OBJECTIVE To evaluate the effect of acarbose on glycemic control and glycemic variability, using a continuous glucose-monitoring system, in patients with type 2 diabetes mellitus who were not well controlled on metformin and vildagliptin therapy. DESIGN Multicenter, randomized, double-blind, placebo-controlled study. SETTING Clinical research units at three hospitals in Italy. PATIE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diabetes care

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2006