Bioimpedance Spectroscopy for Assessment of Volume Status in Patients before and after General Anaesthesia

نویسندگان

  • Matthäus Ernstbrunner
  • Lisa Kostner
  • Oliver Kimberger
  • Peter Wabel
  • Marcus Säemann
  • Klaus Markstaller
  • Edith Fleischmann
  • Barbara Kabon
  • Manfred Hecking
چکیده

BACKGROUND Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. METHODS Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany) measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of 'normal' extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries). BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student's t-test and multiple linear regression. RESULTS In 71 females aged 45 ± 15 years with body weight 67 ± 13 kg and Duration of anesthesia 154 ± 69 minutes [corrected] duration of anaesthesia 154 ± 68 min, pre- to postoperative fluid overload increased from -0.7 ± 1.1 L to 0.1 ± 1.0 L, corresponding to -5.1 ± 7.5% and 0.8 ± 6.7% of normal extracellular volume, respectively (both p<0.001), after patients had received 1.9 ± 0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.3 ± 0.2 L [corrected]. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15). Net perioperative fluid balance (administered fluid volume minus urinary excretion) was significantly associated with change in extracellular volume (r(2) = 0.65), but was not associated with change in intracellular volume (r(2) = 0.01). CONCLUSIONS Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded plausible results and may become useful to guide intraoperative fluid therapy in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Bioimpedance Spectroscopy for Assessment of Volume Status in Patients before and after General Anaesthesia

There are errors in the " Results " section in the Abstract of the published article. Duration of anesthesia should read 154 ± 69 minutes, and the value for perioperative urinary excretion should read 0.3 ± 0.2 L. The headings for Table 3 are misaligned. Please view the correct Table 3 here. open access article distributed under the terms of the Creative Commons Attribution License, which permi...

متن کامل

Estimation of Body Fluid Volume by Bioimpedance Spectroscopy in Patients with Hyponatremia

PURPOSE Estimation of body fluid volume in hyponatremia is useful for diagnosis and therapeutic decision-making. Physical examination has been generally used to estimate body fluid volume, but it depends on the physician's abilities. Bioimpedance spectroscopy has been suggested to be a reliable method for the estimation of body fluid volume. Therefore, this study investigated whether bioimpedan...

متن کامل

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

Comparison and Reproducibility of Techniques for Fluid Status Assessment in Chronic Hemodialysis Patients.

BACKGROUND Several methods have been developed to assess the hydration status in chronic hemodialysis (HD) patients. The aim of this study was to compare body bioimpedance spectroscopy (BIS) with ultrasound (US) lung comet score (ULCs), B-type natriuretic peptide (BNP) and inferior vena cava diameter (IVCD) by US for the estimation of dry weight before and after HD and to analyze all methods in...

متن کامل

Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study.

BACKGROUND Dry weight assessment (DWA) is essential to efficient therapy of haemodialysis (HD) patients. However, so far objective methods for DWA have not been applicable to daily routine. Thus, exact fluid management in HD remains difficult and is often based on clinical criteria. The aims of this study were (1) to objectively define pre- and post-dialytic ranges of extracellular volume in a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014